10: Line and Tunnel Settings
PremierWave® XC HSPA+ Intelligent Gateway User Guide
68
Using XML
Include in your file:
<statusgroup name=”line” instance=”1”>
The Line Settings allow configuration of the serial lines (ports).
Table 10-1 Line Configuration Settings
Line Settings
Description
Name
Enter a name or short description for the line, if desired. By default, there is
no name specified. A name that contains white space must be quoted.
Interface
Set the interface type for the Line. The default is
RS232
.
Choices are:
RS232
RS485 Full-Duplex
RS485 Half-Duplex
State
Select to enable or disable the operational state of the Line. The default is
Enabled
.
Protocol
Set the operational protocol for the Line. The default is
Tunnel
. Choices are:
None
Tunnel
= Serial-Network tunneling protocol.
Baud Rate
Set the Baud Rate (speed) of the Line. The default is
9600
.
Any set speed between 300 and 921600 may be selected: 300, 600, 1200,
2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600.
When selecting a Custom baud rate, you may manually enter any value
between 300 and 5000000.
Note:
The maximum baud rate in RS232 mode is 1000000 bps. Custom
baud rates are not supported when a line is configured for Command Mode.
Parity
Set the Parity of the Line. The default is
None
.
Data Bits
Set the number of data bits for the Line. The default is
8
.
Stop Bits
Set the number of stop bits for the Line. The default is
1
.
Flow Control
Note:
Set the flow control for the Line. The default is
None
.
Note:
This field becomes available if RS232 or RS485 Full-Duplex is
selected under Interface above.
Gap Timer
Set the Gap Timer delay to Set the number of milliseconds to pass from the
last character received before the driver forwards the received serial bytes.
By default, the delay is four character periods at the current baud rate
(minimum 1 msec).
Threshold
Set the number of threshold bytes which need to be received in order for the
driver to forward received characters.