5: Commands and Levels
reassert
Asserts line status with current configured values.
show
Displays the current status.
show command mode
Shows the command mode settings for the current line.
show history
Displays the last 20 commands entered during the current
CLI session.
show line
Displays the current configuration.
show statistics
Shows the line statistics.
state disable
Disables the line so data cannot be sent/received.
state enable
Enables the line so data can be sent/received.
stop bits 1
Uses one stop bit after data on the line.
stop bits 2
Uses two stop bits after data on the line.
terminal
<line>
Enters the configure-terminal level. <line> = number of the
terminal line (serial port) to be configured.
terminal network
Enters the configure-terminal level for the network.
termination disable
Refrains from terminating the line.
termination enable
Enables 120 ohm line termination in RS485 half-duplex
mode.
threshold
<bytes>
Sets the threshold in bytes. After this many bytes are re-
ceived, they are forwarded without delay.
tunnel
<line>
Enters the tunnel level. <line> = number of the tunnel line
(serial port) to be configured.
write
Stores the current configuration in permanent memory.
xoff char
<control>
Sets the xoff character for use with software flow control
on this line. The character may be input as text, control,
decimal, or hex. A control character has the form <con-
trol>C. A decimal value character has the form \99. A hex
value character has the form 0xFF.
xon char
<control>
Sets the xon character for use with software flow control
on this line. The character may be input as text, control,
decimal, or hex. A control character has the form <con-
trol>C. A decimal value character has the form \99. A hex
value character has the form 0xFF.
line 2 (line:2) level commands
auto show statistics
Continuously displays line statistics.
baud rate
<bits per second>
Sets the line speed. <bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600, 19200,
and so on.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command mode.
command mode echo serial string disable
Disables user-defined serial boot string to be echoed in
the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in
the CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter
command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to enter
command mode. <string> = text with possible binary
characters. Within [] use binary decimal up to 255 or hex
PremierWave® XC Intelligent Gateway Command Reference
208