5: Commands and Levels
alarm message
<text>
Sets the email message to be sent when the alarm turns
on.
alarm reminder interval
<minutes>
Sets the time interval that messages will be sent while the
alarm remains on.
clrscrn
Clears the screen.
default alarm email
Specifies no email when the alarm turns on.
default normal email
Specifies no email when the alarm turns off.
exit
Exits to the next higher level.
no alarm message
Removes the alarm email message.
no alarm reminder interval
Only one message will be sent when the alarm turns on.
no normal message
Removes the normal email message.
no normal reminder interval
Only one message will be sent when the alarm turns off.
normal email email
<number>
Specifies the email number to send when the alarm turns
off.
normal email none
Specifies no email when the alarm turns off.
normal message
<text>
Sets the email message to be sent when the alarm turns
off.
normal reminder interval
<minutes>
Sets the time interval that messages will be sent while the
alarm remains off.
show
Shows the current configuration.
show history
Displays the last 20 commands entered during the current
CLI session.
write
Stores the current configuration in permanent memory.
email (config-action-email:digital input 2 state change) level commands
alarm email email
<number>
Specifies the email number to send when the alarm turns
on.
alarm email none
Specifies no email when the alarm turns on.
alarm message
<text>
Sets the email message to be sent when the alarm turns
on.
alarm reminder interval
<minutes>
Sets the time interval that messages will be sent while the
alarm remains on.
clrscrn
Clears the screen.
default alarm email
Specifies no email when the alarm turns on.
default normal email
Specifies no email when the alarm turns off.
exit
Exits to the next higher level.
no alarm message
Removes the alarm email message.
no alarm reminder interval
Only one message will be sent when the alarm turns on.
no normal message
Removes the normal email message.
no normal reminder interval
Only one message will be sent when the alarm turns off.
normal email email
<number>
Specifies the email number to send when the alarm turns
off.
normal email none
Specifies no email when the alarm turns off.
normal message
<text>
Sets the email message to be sent when the alarm turns
off.
normal reminder interval
<minutes>
Sets the time interval that messages will be sent while the
alarm remains off.
show
Shows the current configuration.