8: Line and Tunnel Settings
PremierWave® XN Intelligent Gateway User Guide
87
Connecting Multiple Hosts
If more than one host is configured, a
Host Mode
option appears. Host Mode controls how
multiple hosts will be accessed. For the PremierWave device, the Connect Mode supports up to 32
hosts. Hosts may be accessed sequentially or simultaneously:
Sequential
– Sequential host lists establish a prioritized list of tunnels. The host specified as
Host 1 will be attempted first. If that fails, it will proceed to Host 2, 3, etc, in the order they are
specified. When a connection drops, the cycle starts again with Host 1 and proceeds in order.
Establishing the host order is accomplished with host list promotion (see
). Sequential is the default Host Mode.
Simultaneous
– A tunnel will connect to all hosts accepting a connection. Simultaneous
connections occur at the same time to all listed hosts. The device can support a maximum of
64 total aggregate connections.
Host List Promotion
This feature allows Host IP promotion of individual hosts in the overall sequence.
To promote a specific Host:
1. Click the
icon in the desired Host field, for example Host 2 and Host 3.
2. The selected Host(s) exchanges its place with the Host above it.
3. Click
Submit
. The hosts change sequence.
Disconnect Mode
Specifies the optional conditions for disconnecting any Accept Mode or Connect Mode connection
that may be established. If any of these conditions are selected but do not occur and the network
disconnects to the device, a Connect Mode connection will attempt to reconnect. However, if none
of these conditions are selected, a closure from the network is taken as a disconnect.
Table 8-7 Tunnel Disconnect Mode Settings
Tunnel Disconnect
Mode Settings
Description
Stop Character
Enter the Stop Character which, when received on the Serial Line, disconnects the
tunnel. The Stop Character may be designated as a single printable character or
as a control character. Control characters may be input in any of the following
forms: <control>J or 0xA(hexadercimal) or \10 (decimal). Disable the Stop
Character by blanking the field to set it to <None>.
Modem Control
Set whether Modem Control enables disconnect when the Modem Control pin is not
asserted on the Serial Line. Choices are:
Enabled
Disabled
(default)
Timeout
Enter the number of milliseconds a tunnel may be idle before disconnection. The
value of zero disables the idle timeout.
Flush Serial Data
Set whether to flush the Serial Line when the Tunnel is disconnected. Choices are:
Enabled
Disabled
(default)