5: Commands and Levels
SGX™ 5150 IoT Device Gateway Command Reference
358
terminal network
Enters the configure-terminal level for the network.
terminal type
<text>
Sets the terminal type.
tunnel
<line>
Enters the tunnel level. <line> = number of the tunnel line (serial port) to be configured.
usb
<line>
Enters the usb level. <line> = number of the line (usb port) to be configured.
write
Stores the current configuration in permanent memory.
terminal 4 (config-terminal:4) level commands
bluetooth serial
<line>
Enters the bluetooth serial level. <line> = number of the line (bluetooth serial port) to be
configured.
break duration
<millisec-
onds>
Sets how long a break should last when it is being sent to the line. <milliseconds> = num-
ber of milliseconds.
clrscrn
Clears the screen.
default break duration
Restores the break duration to the default value (500 ms).
default terminal type
Sets the default terminal type, 'UNKNOWN'.
echo disable
Disables echoing of characters received on the line back to the line.
echo enable
Enables echoing of characters received on the line back to the line.
exit
Exits to the configuration level.
exit connect menu disa-
ble
On the login connect menu, removes the menu item allowing the user to exit to the CLI.
exit connect menu ena-
ble
On the login connect menu, inserts the menu item allowing the user to exit to the CLI.
line
<line>
Enters the line level. <line> = number of the line (serial port) to be configured.
login connect menu disa-
ble
Disables the login connect menu, so a user will get the CLI immediately after logging in.
login connect menu ena-
ble
Enables the login connect menu, so a user will get the menu rather than the CLI immedi-
ately after logging in.
no send break
Removes the configured send break character.
preview connect menu
Shows the layout of the connect menu with current settings.
send break
<control>
Sets the optional send break character. <text> = the character. The character may be input
as text, control, decimal, or hex. A control character has the form <control>C. A decimal
value character has the form \99. A hex value character has the form 0xFF.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current CLI session.
terminal
<line>
Enters the configure-terminal level. <line> = number of the terminal line (serial port) to be
configured.
terminal network
Enters the configure-terminal level for the network.
terminal type
<text>
Sets the terminal type.
tunnel
<line>
Enters the tunnel level. <line> = number of the tunnel line (serial port) to be configured.
usb
<line>
Enters the usb level. <line> = number of the line (usb port) to be configured.
write
Stores the current configuration in permanent memory.
terminal network (config-terminal:network) level commands
bluetooth serial
<line>
Enters the bluetooth serial level. <line> = number of the line (bluetooth serial port) to be
configured.
break duration
<millisec-
onds>
Sets how long a break should last when it is being sent to the line. <milliseconds> = num-
ber of milliseconds.
clrscrn
Clears the screen.
default break duration
Restores the break duration to the default value (500 ms).
default terminal type
Sets the default terminal type, 'UNKNOWN'.
echo disable