Lantronix
SISPM1040-582-LRT CLI Reference
33757 Rev. J
Page
175
of
272
Command
:
always-on-poe
Description
:
Show Always-On PoE Status. If enabled, during a switch restart or firmware upgrade, when the
switch warm restarts, it will continue supplying PoE power to the PDs (
FW VB7.10.2658 and
after). FW VB7.20.0039
modified "Always On PoE" software behavior; the feature is enabled and
shown on web UI after upgrading FW to FW VB7.20.0039 or above (default value is off).
Syntax :
show
always-on-poe
Parameters:
Example
:
SISPM1040-582-LRT#
show always-on-poe
Always-on PoE Status : Disable
SISPM1040-582-LRT#
SISPM1040-582-LRT(config)#
always-on-poe
Always-on PoE Status : Enable
SISPM1040-582-LRT(config)#
Command
:
ntp
Description
:
Show NTP status.
Syntax
:
show
ntp status
Parameters
:
Example
:
SISPM1040-582-LRT#
show ntp status
NTP Mode : enabled
Idx Server IP host address (a.b.c.d) or a host name string
--- ------------------------------------------------------
1 192.168.1.30
2
3
4
5