background image

Lantronix 

 

SISPM1040-xxxx-L3 Install Guide 

33855 Rev. A 

              

https://www.lantronix.com/

 

10 

Front Panels 

The switch front panel provides the LEDs, ports, and Reset button as shown and described below. 

 

 

 

SISPM1040-2248-L3 

 

SISPM1040-3248-L3

 

 

SISPM1040-3166-L3 

 

 

Summary of Contents for SISPM1040 L3 Series

Page 1: ...SISPM1040 xxxx L3 Layer 3 Managed Hardened PoE Switch family SISPM1040 2248 L3 SISPM1040 3248 L3 and SISPM1040 3166 L3 Install Guide Part Number 33855 Revision A June 2022...

Page 2: ...ntronix com technical support Sales Offices For a current list of our domestic and international sales offices go to www lantronix com about contact Disclaimer All information contained herein is prov...

Page 3: ...e Switch on Desk or Shelf 16 Installing SFP SFP Modules 17 Installing DAC Cables 17 Connecting Powered Devices PDs 18 Connecting to AC Power 18 Connect the DC Power Wires 19 Power Disconnection 19 Con...

Page 4: ...de 33855 Rev A https www lantronix com 4 LED Troubleshooting 31 Compliance and Safety Information 33 Declaration of Conformity 33 FCC Regulations 33 High Risk Activities Disclaimer 34 Cautions and War...

Page 5: ...PoE ports four 100 1000 dual speeds SFP ports and four 1G 10G SFP slots SISPM1040 3248 L3 Rack mountable hardened L3 switch with 136Gbps switching capacity twenty four 10 100 1000 PoE ports four 100 1...

Page 6: ...vision History on page 2 Features The SISPM1040 xxxx L3 includes these features L3 features for better manageability security QoS and performance Router OSPF OSPFv3 RIP Device Management System DMS bu...

Page 7: ...y 10 to 90 non condensing Data Rate 59 523 Mpps Max Frame Size 10056 Bytes MTBF GB GC Ground Benign Controlled SISPM1040 2248 L3 270 786 Hrs 25 00 deg C SISPM1040 2248 L3 59 411 Hrs 75 00 deg C SISPM1...

Page 8: ...ligent Transportation System ITS Oil and gas field sites Where routing between VLANs is needed where different areas e g intersections or types of data video images signals must be partitioned Where O...

Page 9: ...and birth defects or other reproductive harm Wash hands after handling Unpacking 1 Carefully unpack all SISPM1040 xxxx L3 contents 2 Verify receipt of all SISPM1040 xxxx L3 components see Package Con...

Page 10: ...xxxx L3 Install Guide 33855 Rev A https www lantronix com 10 Front Panels The switch front panel provides the LEDs ports and Reset button as shown and described below SISPM1040 2248 L3 SISPM1040 3248...

Page 11: ...Green On The switch is powered ON correctly Off The switch is not receiving power from DC power Power3 Green On The switch is powered ON correctly Off The switch is not receiving power from AC power...

Page 12: ...ice and the connection speed is 100Mbps Amber Blinking The port is transmitting receiving packets and the connection speed is 100Mbps Off The port has no active network cable connected or it is not es...

Page 13: ...efaults To restore the switch back to its original factory default settings Note Based on the table below users can easily judge which task is being performed by reading the LED behaviors while pressi...

Page 14: ...lled in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may exceed room ambient Install the equipment in an environment compatible with the maximum ambie...

Page 15: ...tion The installer must ensure that the switch is properly grounded during and after installation After the Switch is mounted and connected the front panel grounding screw can be used for grounding Gr...

Page 16: ...g Brackets to the Switch 2 Place the switch on a rack shelf in the rack Push it in until the oval holes in the brackets align with the mounting holes in the rack posts 3 Attach the brackets to the pos...

Page 17: ...eters are passive and those longer than 7 meters are active but this may vary between vendors SFP Direct Attach Copper DAC is a popular choice for 10G Ethernet reaches up to 10 meters due to low laten...

Page 18: ...3at 50VDC 802 3bt 52VDC Not meeting this PSEout requirement may cause power up failures or power cycling with devices drawing maximum power with maximum cable loss Power can be from either of the two...

Page 19: ...pe over the circuit breaker handle to prevent accidental power restoration while you are working on the circuit 2 Insert the negative positive DC wires into the V V DC Power Input terminals respective...

Page 20: ...ver to tighten the wire clamp screws on the front of the terminal block connector Connecting DI DO Relay Wires Note Digital output relay 24VDC 1A Digital input level 0 Low 0V to 6V level 1 High 10V to...

Page 21: ...will automatically switch to abnormal and send a signal to connected devices switch will have system recorded For example a water level application Setting low water level DI normal High water level...

Page 22: ...d against Short Circuit Overload Over Voltage Overheating Convection air cooling DIN rail mountable UL 508 approved Full load burn in test RoHS compliant Specifications Output Output Voltage 48VDC Cur...

Page 23: ...IEC60068 2 6 Vibration EMC Emission EN55011 EN5032 CISPR32 EN61204 3 Class B EN61000 3 2 EN61000 3 3 EMC Immunity EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 E...

Page 24: ...SISPM1040 xxxx L3 Install Guide 33855 Rev A https www lantronix com 24 Power Supply Dimensions 25160 Width 85 5 mm 3 36 in Height 125 2 mm 4 92 in Depth 128 5 mm 5 05 in ADMISSIBLE DIN RAIL TS35 7 5 O...

Page 25: ...25160 Terminal Pin No Assignment TB1 Pin No Assignment 1 FG 2 AC N 3 AC L Terminal Pin No Assignment TB2 Pin No Assignment 1 2 DC OUTPUT V 3 4 DC OUTPUT V 5 6 Relay Contact 7 8 NC DC OK Relay Contact...

Page 26: ...3 switch This standalone power supply can be installed in a 19 Rack with 1RU high The Power Supply provides 340W at 56VDC and is targeted for PoE applications The Power Supply is fully compliant with...

Page 27: ...Change adapter settings on the left of the PC screen Note You can also skip steps a to c by pressing WinKey R and type ncpa cpl command to get directly to step 3 d Select the radio button Use the foll...

Page 28: ...ch the RJ 45 serial port on the switch front panel to the cable for Telnet CLI configuration 3 Attach the other end of the DB 9 cable to a PC running Telnet or a terminal emulation program such as Hyp...

Page 29: ...page 13 8 If using the CLI try configuring via the Web UI and vice versa See the Web User Guide or the CLI Reference PoE Troubleshooting 1 Note that PoE devices initially draw more power during their...

Page 30: ...ature range and take corresponding actions to resolve RJ45 Ports left side SFP Ports SFP Ports LED is Off The port is not connected or the connection is not working 1 Check if the cable connector plug...

Page 31: ...On An abnormal state such as overload status has been detected in the switch Off The port has no active network cable connected or it is not connected a PoE PD device Otherwise the port may have been...

Page 32: ...stablished a link to connected device and the connection speed is 1Gbps Green Blinking The port is transmitting receiving packets and the connection speed is 1Gbps Off The port has no active network c...

Page 33: ...tion on file at the above address this product carries the CE Mark I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standards s Place Minnetonk...

Page 34: ...bserve all electrostatic discharge precautions Failure to observe this caution could result in damage to or failure of the power module Warnings Warning Do not connect the power module to an external...

Page 35: ...ten worden ge nstalleerd S curit lectrique IMPORTANT Cet quipement doit tre utilis conform ment aux instructions de s curit S hk turvallisuus T RKE T m laite on asennettava turvaohjeiden mukaisesti Si...

Page 36: ...Irvine Center Drive Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices For a curre...