Lantronix
SM12XPA Install Guide
33847 Rev. B
33
AC 220V Input
Device Status
Device Operation
Interface
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Non-loading
None
220
0.160
0.606
35.20
21.33
Standby mode
1 minute
10G SFP+ x 12
25G SFP28 x 2
220
0.191
0.695
42.02
29.20
Full-loading
60 minutes later
10G SFP+ x 12
25G SFP28 x 2
220
0.205
0.725
45.10
32.70
Note
: Apparent Power (VA) = AC Voltage x AC Current Consumption.
Real Power (W) = Apparent Power (VA) x Power Factor
AC 240V Input
Device Status
Device Operation
Interface
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Non-loading
None
240
0.164
0.544
39.36
21.41
Standby mode
1 minute
1G RJ45 x 24
10G SFP+ x 4
240
0.192
0.636
46.08
29.31
Full-loading
60 minutes later
1G RJ45 x 24
10G SFP+ x 4
240
0.204
0.672
48.96
32.90
Note
: Apparent Power (VA) = AC Voltage x AC Current Consumption
Real Power (W) = Apparent Power (VA) x Power Factor
AC 264V Input
Device Status
Device Operation
Interface
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Non-loading
None
264
0.169
0.475
44.62
21.19
Standby mode
1 minute
1G RJ45 x 24
10G SFP+ x 4
264
0.194
0.572
51.22
29.30
Full-loading
60 minutes later
1G RJ45 x 24
10G SFP+ x 4
264
0.206
0.604
54.38
32.85
Note
: Apparent Power (VA) = AC Voltage x AC Current Consumption
Real Power (W) = Apparent Power (VA) x Power Factor