Static Table
This page lets you configure Static IP Source Guard Table parameters. You can use the Static IP Source Guard
Table configure to manage the entries.
To configure Static IP Source Guard in the web UI:
1.
Click Security, IP Source Guard and Static Table.
2.
Click “Add New Entry”.
3.
Specify the Port, VLAN ID, IP Address, and MAC address in the entry.
4.
Click Apply.
Figure 11-3.2: Static IP Source Guard Table
Parameter descriptions
:
Port
: At the dropdown select the logical port for the settings.
VLAN ID
: The VID for the settings.
IP Address
: Allowed Source IP address.
MAC address
: Allowed Source MAC address.
Buttons
Add New Entry
: Click to add a new entry to the Static IP Source Guard table. Specify the Port, IP address, and
MAC address for the new entry. Click "Apply".
Delete
: Check to delete the entry. It will be deleted during the next save.
Apply
: Click to save changes.