SM12XPA Web User Guide
33848 Rev. A
Page
246
of
473
Views
Configure SNMPv3 View on this page. The Entry index keys are OID Subtree and View Name. The maximum
number of Views supported is 12.
Web Interface
To configure SNMP Views in the web UI:
1.
Click SNMP, SNMPv3, and Views.
2.
Click Add New Entry.
3.
Specify the SNMP View parameters.
4.
Click Apply. To modify or clear the settings click Reset.
Figure 13-2.4: SNMP View Configuration
Parameter descriptions
:
View
Name
: A string identifying the view name that this entry should belong to. The allowed string length is
1 - 31 characters, and the allowed content is ASCII characters 33 - 126.
View
Type
: Indicates the view type that this entry should belong to. Possible view types are:
Included
: An optional flag to indicate that this view subtree should be included.
Excluded
: An optional flag to indicate that this view subtree should be excluded. In general, if a view
entry's view type is 'Excluded', there should be another view entry existing with view type as 'Included'
and it's OID subtree should overstep the 'Excluded' view entry.
OID
Subtree
: The OID defining the root of the subtree to add to the named view. The allowed OID length is
1 - 128. The allowed string content is a digital number or an asterisk (*).
Object Identifiers (OIDs) uniquely
identify or name MIB variables in the tree.
Buttons
Add New Entry
: Click to add a new entry to the table. Specify the name, configure the new entry, and click
"Apply".
Delete
: Check to delete the entry. It will be deleted during the next save.
Apply
: Click to save changes.
Reset
: Click to undo any changes made locally and revert to previously saved values.