Lantronix
SM12XPA Web User Guide
33848 Rev. A
Page
301
of
473
Mark RED Enable
: The
FlowMeterMarkAllFramesRedEnable
parameter contains a Boolean value that indicates
whether the
MarkAllFramesRed
function is enabled (TRUE) or disabled (FALSE).
Mark RED
: The
FlowMeterMarkAllFramesRed
parameter contains a Boolean value that indicates whether, if the
MarkAllFramesRed
function is enabled, all frames are to be discarded (TRUE) or not (FALSE).
MEF interpretation of color
: MEF Bandwidth Profiles use three color indications:
Green
: “Committed” frames. Service Level Objectives such as frame loss rate, delay, delay variation, etc.
are applicable to these frames. In theory, with proper policing at the edge of the network and proper
allocation of buffer and bandwidth resources within the network, it is possible to guarantee lossless and
timely delivery of all committed frames.
Yellow
: “Excess” frames. Service Level Objectives are not applicable to these frames. Excess frames are
delivered on a “best effort” basis.
Red
: “Non-conformant” frames that are always discarded.
S
https://www.ieee802.org/1/files/public/docs2013/new-tsn-haddock-flow-metering-in-Q-0113-
Buttons
Add New Entry
: Click to add a new row to the table.
Apply
: Click to save changes.
Reset
: Click to undo any changes made locally and revert to previously saved values.