Stream Filter Statistics
This page displays current PSFP statistics parameters.
Figure 18-2.3.3: PSFP Stream Filter Statistics
Parameter descriptions
:
Clear
: This box is used to mark an entry for clearance in the next Clear operation.
SFI ID
: The
MaxStreamFilterInstances
parameter defines the maximum number of stream filter instances that
are supported by this Bridge component.
Matching Frame Count
: The
MatchingFramesCount
counter counts received frames that match this stream
filter.
Passing Frame Count
: The
PassingFramesCount
counter counts received frames that pass the gate associated
with this stream filter.
Not Passing Frame Count
: The
NotPassingFramesCount
counter counts received frames that do not pass the
gate associated with this stream filter.
Passing SDU Count
: The
PassingSDUCount
counter counts received frames that pass the SDU size filter
specification associated with this stream filter.
Not Passing SDU Count
: The
NotPassingSDUCount
counter counts received frames that do not pass the SDU
size filter specification associated with this stream filter.
RED Frames Count
: The REDFramesCount counter counts received random early detection (RED) frames
associated with this stream filter.
Buttons
Auto-refresh
: Check this box to refresh the page automatically every 3 seconds.
Refresh
: Click to refresh the page immediately.
Clear
: Clears the blocked flag for selected entries.
Clear
All