Lantronix
SM12XPA Web User Guide
33848 Rev. A
Page
317
of
473
FRER
FRER Status
This page lets you view, reset, and clear current FRER (Frame Replication and Elimination for Reliability) status.
IEEE 802.1Qca integrates control protocols to manage multiple topologies, configure an explicit forwarding path
(a predefined path for each stream), reserve bandwidth, provide data protection and redundancy, and distribute
flow synchronization and flow control messages.
Figure 18-2.4.1: FRER Status
Parameter descriptions:
Instance
: The ID of the FRER instance.
Oper
: The operational state of the FRER instance.
up
: Active.
down
: Disabled or Internal error.
Warning
: Operational warnings of the FRER instance.
up
: No warnings.
down
: There are warnings, use tooltip to see.
Latent
Error
:
up
: No errors.
down
: There are latent errors.
Statistics
: Check to reset statistics counters.
Reset
Function
: Click to perform a reset function.
If this FRER instance is in generation mode, this is used to reset the sequence number of the sequence
generator.
If this FRER instance is in recovery mode, this is used to reset the recovery function. It resets both
possible individual recovery functions and the compound recovery functions.
Reset
Latent
Error
: Click to clear a sticky latent error.
Buttons
Auto-refresh
: Check this box to refresh the page automatically every 3 seconds.
Refresh
: Click to refresh the page immediately.
Clear
: Clears the blocked flag for selected entries.
Clear
all
: Clears the blocked flag for all entries.