Event Settings
This page lets you set and view current Link OAM Link Event parameters.
Figure 3-6.2: Link Event Configuration for Port 1
Port
: The switch port number.
Event Name
: Name of the Link Event which is being configured.
Error Window
: Represents the window period in the order of 1 second for observation of various link events.
Error Threshold
: Represents the threshold value for the window period for the appropriate Link event so as to
notify the peer of this error.
Error Frame Event
: Counts the number of errored frames detected during the specified period. The period is
specified by a time interval ( Window in order of 1 sec). This event is generated if the errored frame count is
equal to or greater than the specified threshold for that period (Period Threshold). Errored frames are frames
that had transmission errors as detected at the Media Access Control sublayer. Error Window for 'Error Frame
Event' must be an integer value between 1-60 and its default value is '1'. Whereas Error Threshold must be
between 0-4294967295 and its default value is '1'.
Symbol Period Error Event
: Counts the number of symbol errors that occurred during the specified period. The
period is specified by the number of symbols that can be received in a time interval on the underlying physical
layer. This event is generated if the symbol error count is equal to or greater than the specified threshold for
that period. Error Window for 'Symbol Period Error Event' must be an integer value between 1-60 and its default
value is '1'. Whereas Error Threshold must be between 0-4294967295 and its default value is '1'.
Seconds Summary Event
: The Errored Frame Seconds Summary Event TLV counts the number of errored frame
seconds that occurred during the specified period. The period is specified by a time interval. This event is
generated if the number of errored frame seconds is equal to or greater than the specified threshold for that
period. An errored frame second is a one second interval wherein at least one frame error was detected.
Errored frames are frames that had transmission errors as detected at the Media Access Control sublayer.
Error Window for 'Seconds Summary Event' must be an integer value between 10-900 and its default value is
'60'. Whereas Error Threshold must be 0-65535 and its default value is '1'.
Buttons
Port select box
: determines which port is affected by clicking the buttons.
Save
: Click to save changes.
Reset
: Click to undo any changes made locally and revert to previously saved values.