Event Status
The left pane displays the Event status for the Local OAM unit while the right pane displays the status for the
Peer for the respective port.
Figure 3-6.5: Detailed Link OAM Link Status for Port 1
Parameter descriptions
:
Port
: The switch port number.
Sequence Number
: This two-octet field indicates the total number of events occurred at the remote end.
Frame Error Event Timestamp
: This two-octet field indicates the time reference when the event was generated,
in terms of 100 ms intervals.
Frame error event window
: This two-octet field indicates the duration of the period in 100 ms intervals.
The default value is one second. The lower bound is one second and the upper bound is one minute.
Frame error event threshold
: This four-octet field indicates the number of detected errored frames in the
period is required to be equal to or greater than for the event to be generated. The default value is one frame
error. The lower bound is zero frame errors, and the upper bound is unspecified.
Frame errors
: This four-octet field indicates the number of detected errored frames in the period.
Total frame errors
: This eight-octet field indicates the sum of errored frames that have been detected since the
OAM sublayer was reset.
Total frame error events
: This four-octet field indicates the number of Errored Frame Event TLVs that have
been generated since the OAM sublayer was reset.
Frame Period Error Event Timestamp
: This two-octet field indicates the time reference when the event was
generated, in terms of 100 ms intervals.
Frame Period Error Event Window
: This four-octet field indicates the duration of period in terms of frames.