Stream Gate Status
This page lets you view and set current PSFP SGI (Stream Gate Instance) status.
Figure 18-2.3.4: PSFP SGI Status
Parameter descriptions
:
SGI ID
: The Stream Gate Instance parameter is an index in the Stream Gate table.
Oper Gate Enabled
: The Gate Enabled parameter determines whether the stream gate is active (true) or
inactive (false).
Oper Gate States
: The operational value of the
GateStates
parameter for the stream gate. The open value
indicates that the gate is open, the closed value indicates that the gate is closed.
Cycle Time
Numerator
: The operational value of the numerator of the
CycleTime
parameter for the gate.
The numerator and denominator together represent the cycle time as a rational number of seconds.
Cycle Time
Denominator
: The operational value of the denominator of the
CycleTime
parameter for the gate.
The numerator and denominator together represent the cycle time as a rational number of seconds.
Cycle Time Extension
: The operational value of the
CycleTimeExtension
parameter for the gate. The value is an
unsigned integer number of nanoseconds.
Base Time
: The operational value of the
BaseTime
parameter for the gate. The value is a representation of a
PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds.
Current Time
: The current time, in PTPtime, as maintained by the local system. The value is a representation of
a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds.
Only the seconds are displayed.
Config Change Time
: The PTPtime at which the next config change is scheduled to occur. The value is a
representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number
of nanoseconds.
Config Change Error
: A counter of the number of times that a re-configuration of the traffic schedule has been
requested with the old schedule still running and the requested base time was in the past.
Tick Granularity
: The granularity of the cycle time clock, represented as an unsigned number of tenths of
nanoseconds.
Config Pending
: The value of the
ConfigPending
state machine variable. The value is TRUE if a configuration
change is in progress but has not yet completed.