4: Configuration Using Web Manager
WiPort Embedded Wireless Device Server User Guide
35
Mode. The unit will not accept a data connection from a
remote device when the host list option is enabled.
LED
Select
Blink
for the status LEDs to blink upon connection or
None
for no LED output.
Disconnect Mode
On Mdm_Ctrl_In Drop
Set to
Yes
for the network connection to or from the serial port
to drop when
Modem Control In
transitions from a high state
to a low state.
Hard Disconnect
When set to
Yes
, the TCP connection closes even if the
remote site does not acknowledge the disconnect request.
Check EOT (Ctrl-D)
Select
Yes
to drop the connection when
Ctrl-D
or
Hex 04
is
detected. Both
Telnet Com Port Cntrl
and
Check EOT
(Ctrl-D)
must be enabled for
Disconnect with EOT
to
function properly.
Ctrl-D
is only detected going from the serial
port to the network. The default setting is No.
Inactivity Timeout
Use this parameter to set an inactivity timeout. The unit drops
the TCP connection to port 10001/10002 if there is no activity
on the serial line before the set time expires. Enter time in the
format mm:ss, where m is the number of minutes and s is the
number of seconds. To disable the inactivity timeout, enter
00:00
.
Note:
The default port number for Port 1 is 10001 and 10002
for Port 2. However, port numbers may be set to a different
value.
3. When you are finished, click the
OK
button.
4. On the main menu, click
Apply Settings
.
Connection Settings - UDP
To configure a channel’s UDP settings
:
1. From the main menu, click
Connection
for either Channel 1 or Channel 2 to
display the Connection Settings page for the selected channel.
2. In the available fields, enter the following information:
Connect Protocol
Protocol
Select
UDP
from the pull down menu.