WiPort™ User Guide
71
9
9
:
:
T
T
r
r
o
o
u
u
b
b
l
l
e
e
s
s
h
h
o
o
o
o
t
t
i
i
n
n
g
g
This chapter discusses how you can diagnose and fix errors quickly without having to
contact a dealer or Lantronix. The WiPort’s diagnostic LEDs indicate the unit’s
status. It helps to connect a terminal to the serial port while diagnosing an error to
view summary messages that may be displayed. When troubleshooting, always
ensure that the physical connections (power cable, network cable, and serial cable)
are secure.
Note:
Some unexplained errors might be caused by duplicate IP addresses on the
network. Make sure that your unit's IP address is unique.
When troubleshooting the following problems, make sure that the WiPort is powered
up. Confirm that you are using a good network connection.
Diagnostic LED States
Condition
Diagnostic LED
Channel 1 Status LED
No Errors
OFF
N/A
Firmware storage checksum
error
ON
Blink 1x/4 seconds
RAM error
ON
Blink 2x/4 seconds
Network controller error
ON
Blink 3x/4 seconds
Serial number storage
checksum error
ON
Blink 4x/4 seconds
Duplicate IP address present
ON
Blink 5x/4 seconds
Firmware and hardware
mismatch
ON
Blink 6x/4 seconds
Faulty network connection
Blink 2x/second
Blink 4x/4 seconds
No DHCP response
Blink 2x/second
Blink 5x/4 seconds
Setup menu active
Blink 2x/second
Follow Diagnostic LED for 2
seconds, off for 2 seconds