background image

2:Description and Specifications 

XPort Direct™ Integration Guide/Data Sheet

 

 

12

 

 

Figure 2-7. Side View 

 

Recommended PCB Layout 

The following drawing shows the hole pattern and mounting dimensions for the XPort 
Direct. 

Figure 2-8. PCB Layout (Top View) 

 

 

Summary of Contents for XPort Direct

Page 1: ...Part Number 900 469 Revision B May 2007 XPort Direct Integration Guide Data Sheet ...

Page 2: ...is equipment in a residential area is likely to cause interference in which case the user at his or her own expense will be required to take whatever measures may be required to correct the interference Note This product has been designed to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmfu...

Page 3: ... THE NINETY 90 DAY PERIOD THERE IS NO WARRANTY OR CONDITION OF ANY KIND Any supplements or updates to the Product including without limitation any if any service packs or hot fixes provided to you after the expiration of the ninety day Limited Warranty period are not covered by any warranty or condition express implied or statutory LIMITATION ON REMEDIES If the Product does not meet this Limited W...

Page 4: ...t obtaining an export license or determining that an exception is applicable APPLICABLE LAW If you acquired this Product in the United States this LICENSE is governed by the laws of the State of California without reference to any conflict of laws principles All disputes arising out of this LICENSE in the United States shall be subject to the exclusive jurisdiction of the state and federal courts ...

Page 5: ...oard Schematics_________________________________________________13 Technical Specifications _________________________________________________16 A Compliance 17 B Warranty 18 List of Figures Figure 2 1 Side View of the XPort Direct __________________________________________7 Figure 2 2 XPort Direct Block Diagram ___________________________________________8 Figure 2 3 RTS Connection for RS485 Mode _...

Page 6: ...e the XPort Direct device networking gateway into their product Additional Documentation The following documentation is available on the product CD and the Lantronix Web site www lantronix com XPort Direct User Guide Provides information needed to configure use and update the XPort Direct firmware XPort Direct Quick Start Provides instructions for getting your unit up and running ...

Page 7: ...ernet converter empowers original equipment manufacturers OEMs to quickly and easily go to market with networking and web page serving capabilities built into their products The XPort Direct The XPort Direct contains Lantronix s own DSTni EX CPU which has 256 KB zero wait state SRAM 16 Kbytes of boot ROM and an integrated 10 100 Ethernet MAC PHY The following diagram shows the side view of the XPo...

Page 8: ...ships of the components Figure 2 2 XPort Direct Block Diagram TXD RXD RTS DTR CTS MOSI MISO CS SCK TX TX RX RX LEDs CLOCK PHY DSTni PCB Interface Data Out Data In RTS DTR CTS 3 3V GND 1 2 3 7 9 11 13 15 Reserved Reserved CP1 CP2 17 19 21 23 Reset 5 RESET Filter 3 3V Analog 3 3V Digital 1 8V Reg 1 8V CP1 CP2 Reserved Reserved 1Mbit SPI Flash RJ45 W Integrated Mag and LEDs 25Mhz Crystal ...

Page 9: ...Data In 9 Serial data in read by DSTni s built in UART RTS 11 Flow control out RTS Request to Send output driven by DSTni s built in UART for connection to CTS of attached device RTS is used as transmit enable in RS485 mode DTR 13 Modem control DTR Data Terminal Ready output driven by DSTni s built in UART for connection to DCD of attached device CTS 15 Flow control in CTS Clear to Send input read...

Page 10: ...ntial Ethernet transmit data RX In 3 Differential Ethernet receive data RX In 6 Differential Ethernet receive data Not used 4 Terminated Not used 5 Terminated Not used 7 Terminated Not Used 8 Terminated SHIELD Chassis ground LEDs The XPort Direct contains the following LEDs Link Green LED Activity Yellow LED Table 2 3 LEDs Link LED Activity LED Status Meaning Status Meaning Off No link Off No Acti...

Page 11: ...Description and Specifications XPort Direct Integration Guide Data Sheet 11 Dimensions The following drawings show the dimensions of the XPort Direct in inches Figure 2 5 Front View Figure 2 6 Bottom View ...

Page 12: ...ecifications XPort Direct Integration Guide Data Sheet 12 Figure 2 7 Side View Recommended PCB Layout The following drawing shows the hole pattern and mounting dimensions for the XPort Direct Figure 2 8 PCB Layout Top View ...

Page 13: ...2 Description and Specifications XPort Direct Integration Guide Data Sheet 13 Demo Board Schematics Figure 2 9 XPort Direct Demo Board ...

Page 14: ...2 Description and Specifications XPort Direct Integration Guide Data Sheet 14 ...

Page 15: ...2 Description and Specifications XPort Direct Integration Guide Data Sheet 15 ...

Page 16: ...ity Ethernet Version 2 0 IEEE 802 3 electrical Ethernet II frame type Protocols Supported ARP UDP IP TCP IP Telnet ICMP DHCP BOOTP TFTP Auto IP LEDs 10Base T and 100Base TX Link Activity Full half duplex Management Serial login Telnet login Security Password protection locking features Weight 15 5g 0 55 oz Material Plastic shell Temperature 0 C to 70 C 32 F to 140 F operating temperature 40 C to 8...

Page 17: ...afety UL 60950 1 CAN CSA C22 2 No 60950 1 03 Electromagnetic Emissions The XPort Direct has been tested to the following standards VCCI FCC IC CE and AS NZS 30 MHz 1000 MHz Class A Radiated Emissions Note This product has been pre tested to meet FCC Class A Radiated Emissions However because the XPort Direct will be embedded into the OEM s device the OEM must get certification for the end product ...

Page 18: ...nix Lantronix will ship the replacement media to the customer In no event will Lantronix be responsible to the user in contract in tort including negligence strict liability or otherwise for any special indirect incidental or consequential damage or loss of equipment plant or power system cost of capital loss of profits or revenues cost of replacement power additional expenses in the use of existi...