Designation
100Base-FX
Typical Distance
2 Km
Nominal Wavelength
1310 nm
Cable Type
62.5/125 mm
Connector
SC
Optical Budget
15 dB
Serial Interface
5-port 10/100Base-TX or 4-port 10/100Base-TX
8-port 10/100Base-TX
8-port 10/100Base-TX, plus 1-port
plus 1-port 100Base-FX
100Base-FX (optional)
Forward and Filtering Rate
14,880 pps for 10 Mbps
148,810 pps for 100 Mbps
14,880 pps for 10 Mbps
148,810 pps for 100 Mbps
14,880 pps for 10 Mbps
148,810 pps for 100 Mbps
Address Table Size
2048 MAC addresses
2048 MAC addresses
4K MAC addresses
Latency
Less than 5.1
µ
s
Less than 7.1
µ
s
Less than 9.6
µ
s
Reverse Polarity Protection
n/a
n/a
Yes
Network Interface
10/100 Mbps full/half-duplex, auto negotiation,
10/100 Mbps full/half-duplex, auto negotiation,
10/100 Mbps full/half-duplex, auto negotiation,
auto MDI/MDIX
auto MDI/MDIX
auto MDI/MDIX
LED Indicators
Per Unit: Power Status
Per Unit: Power Status (Power 1, Power 2)
Per Unit: Power Status (Power 1, Power 2)
Per Port:10/100TX, 100FX:Link/Activity (Green), Speed (Yellow)
Per Port:10/100TX,100FX:Link/Activity (Green),
Per Port:10/100TX,100FX:Link/Activity (Green),Speed (Yellow)
Speed (Yellow),Fault (Red)
Management
n/a
n/a
RS-232 console,Telnet, SNMP V1 & V2, RMON,
Web browser,TFTP
Alarm Contact
n/a
One relay output with current 1A @ 24 VDC
One relay output with current 1A @ 24 VDC
Standards
IEEE802.3 10Base-T,IEEE802.3u 100 Base-TX/100Base-FX,IEEE802.3x IEEE802.3 10Base-T,IEEE802.3u 100 Base-TX/100Base-FX,IEEE802.3x
IEEE802.3 10Base-T,IEEE802.3u 100 Base-TX/100Base-FX
IEEE802.3x,IEEE802.1Q,IEEE802.1p,IEEE802.1w
Power
Input Voltage: 12 to 48 VDC
Input Voltage: 10 to 48 VDC
Input Voltage: 10 to 30 VDC
Input Current: 0.1A max.
Input Current: 1.5A max.
Input Current: 2A max.
Power Consumption: 2.4W max.
Power Consumption: 24 VDC @ 0.55A, 18.48 W max.
Power Consumption: 24 VDC @ 0.77A, 18.48 W max.
Environmental
Operating Temperature: -10° to 60° ° C (-14° to 140° F)
Operating Temperature: -34° to 74° ° C (-29° to 165° F)
Operating Temperature: -34° to 74° ° C (-29° to 165° F)
Storage Temperature:-25° to 85° C (-13° to 185° F)
Storage Temperature:-40° to 85° C (-40° to 185° F)
Storage Temperature: -40° to 85° C (-40° to 185° F)
Humidity: 10% to 90% relative humidity (non-condensing)
Humidity: 10% to 95% relative humidity (non-condensing)
Humidity: 10% to 95% relative humidity (non-condensing)
Protocols Supported
n/a
n/a
IGMP, GVRP, SNMP V1/V2, RMON,TFTP
Packet Buffer Memory
384 kilobit
768 kilobit
256 KB
Packaging
Plastic case with DIN-rail mounting
Aluminum case with DIN-rail, or panel mounting
Aluminum case with DIN-rail, panel or rack mounting
Dimensions:
25 mm W x 70 mm D x 110 mm H
50 mm W x 110 mm D x 136 mm H
50 mm W x 125 mm D x 135 mm H
(0.99" W x 2.76" D x 4.33" H)
(1.97" W x 4.33" D x 5.35" H)
(1.97" W x 4.92" D x 5.31" H)
Weight:
0.2 Kg (0.44 lbs.)
0.8 Kg (1.76 lb)
0.8 Kg (1.76 lb)
Processing Types
Store-and-forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Standards
IEEE802.3 10Base-T, IEEE802.3u 100 Base-TX/100Base-FX, IEEE802.3x
Regulatory Approvals:
Emission Compliance
FCC Part 15, Class A
ISO
Manufactured in an ISO9001 facility
Safety
UL 60950
UL 60950, EN 60950, IEC 60950, IEC 61000-6-2, UL 1604: Classified for ITE Equipment for use in hazardous locations:
Class 1, Division 2 group A, B, C & D:Temp Code T4A; -25C° < Tamb < 74C°
CE Approval
n/a
EN55022 (CISPR22 Class A), EN55024 (CISPR24 Class A)
ESD Standards (IEC 61000-4-2)
n/a
Enclosure Contact: + / - 4 KV; Criteria B, Enclosure Air: + / - 8 KV; Criteria B
Radiated FRI Standards (IEC 61000-4-3)
n/a
Enclosure Ports:10 V/m,80 to 1000 MHz;Criteria A
Burst Standards (IEC 61000-4-4)
n/a
Enclosure Ports: + / - 4 KV @ 2.5 KHz; Criteria B, DC Power Ports: + / - 4 KV; Criteria B, AC Power Ports: + / - 4 KV; Criteria B
Surge Standards (IEC 61000-4-5)
n/a
Signal Ports: + / - 1 KV; Line-to-earth; Criteria B, DC Power Ports: + / - 0.5 KV; Line-to-earth; Criteria B
AC Power Ports: + / - 2 KV; Line-to-earth; Criteria B
Induced RFI Standards (IEC 61000-4-6)
n/a
Signal Ports: 10V @ 0.15 - 80 MHz; Criteria A, DC Power Ports: 10V @ 0.15 - 80 MHz; Criteria A
AC Power Ports: 10V @ 0.15 - 80 MHz; Criteria A, Earth Ground Ports: 10V @ 0.15 - 80 MHz; Criteria A
Magnetic Field Standards (IEC 61000-4-8)
n/a
Enclosure Ports: 30 A/m @ 50, 60 Hz; Criteria A
Voltage Dip Standards (IEC 61000-4-11)
n/a
AC Power Ports: 30% Reduction for 0.5 period; Criteria B
Environmental Test Compliance
n/a
(IEC 60068-2-6) Vibration Resistance: 5G @ 150 Hz; Criterion 3 (Operation/Storage/Transport)
(IEC 60068-2-27) Shock:
• 5 G @ 11 ms (Half-Sine Shock Pulse; Operation)
• 50 G @ 11 ms (Half-Sine Shock Pulse; Storage/Transport)
(IEC 60068-2-32) Free Fall: 1 M (3.281 ft.)
NEMA TS1/2 Environ.Requirements
n/a
Yes
for Traffic Control Equipment
Installation Type:
DIN Rail (mounting kit is included)
DIN Rail (mounting kit is included)
DIN Rail (mounting kit is included)
Optional wall-mount kit, ordered separately (X9294PMKT-01)
Optional wall-mount or rack-mount kit,ordered separately
(X9294DRKT-01), (X9294PMKT-01)
XPress-Pro SW Model:
52000
92000
94000
Summary of Contents for Xpress-Pro SW 52000
Page 1: ......