Crimping the contacts
Check that contact and cross-section fit together.
Insert the contact with the opening facing upwards into EPIC
®
SOLAR Crimp-Tool.
Insert the wire completely into the crimp area of the contact.
The cable is pushed forward until the insulation strikes the
crimp receptacle of the contact. In this way, the
supermatent is insured at least 2 mm.
Completely squeeze the tool until the trigger lock releases the tool again.
Remove the crimp ad check visually if all strands are completely enclosed.
The strand supernatant after crimping is at least 2 mm.
Explanation of the crimping process
Contact into the crimp insert
Contact into the crimp insert with cable
Strand
supernatant