ASSEMBLY INSTRUCTION

 

 

Valid from: 

17.07.2019

 

EPIC

®

 SOLAR 4 PLUS 

 

Document: L44428235EN 
Version: 02 

Page 6 of 9 

We reserve all rights according to DIN ISO 16016. 

Mounting of EPIC

®

 SOLAR 4 PLUS 

 
Analysing the cable

 

 

 

Find the cross section 

 

Find the outer diameter 

 

 

Item 

Number 

Designation 

Cross section 

in mm² 

Cable 

clamping 

range 

d in mm 

Stripping 

Length 
L [mm] 

Rated 

Current 

 [A] 

 

EPIC

®

 SOLAR 4PLUS Female Connector, field mountable, including Contacts 

44428236  EPIC

®

 SOLAR 4PLUS F 4 mm²  ... 

6 mm² 

4 – 6 

5,2 - 7,1 

30 

44428238  EPIC

®

 SOLAR 4PLUS F 10 mm² 

10 

5,2 – 7,1 

12 

30 

 

EPIC

®

 SOLAR 4PLUS Male Connector, field mountable, including Contacts 

44428235  EPIC

®

 SOLAR 4PLUS M 4mm²  ... 

6mm² 

4 – 6 

5,2 - 7,1 

30 

44428237  EPIC

®

 SOLAR 4PLUS M 10 mm² 

10 

5,2 – 7,1 

12 

30 

 

Preparing the cable 

 
Carefully cut the cabel. The strands shall be without any oxidation or contamination.  
 

Stripping the cable 
 

Stripping length: depending on the table (see table above!). 
The insulation must be removed clean and competed. No stranded wires may be cut off 

 

 

 

Summary of Contents for EPIC SOLAR 4Plus Series

Page 1: ...to DIN ISO 16016 EPIC SOLAR 4 PLUS ASSEMBLY INSTRUCTION Contents Scope of delivery 2 Contacts 2 Technical Specifications 3 Safety Instructions 4 Necessary Tools 5 Mounting of EPIC SOLAR 4 PLUS 6 Analy...

Page 2: ...PLUS is delivered pre assembled the necessary contacts are included separately EPIC SOLAR 4 Plus X Y Item number Designation 44428235 EPIC SOLAR 4 PLUS M 4 0 mm or 6 0 mm 44428236 EPIC SOLAR 4 PLUS F...

Page 3: ...014 Rated Voltage 1 500 V DC Rated Current 30 A 4 0mm 30 A 6 0mm 30 A 10 mm Rated impulse withstand voltage 16 kV Rated temperature 40 C 85 C Upper Limit of Temperature 105 C Protection degree IP68 10...

Page 4: ...DC 1 5 kV max Voltage DC 1 8 kV Conductor Earth System without Earth Connection Mated connectors are IP68 protected 1m 10 h A permanent use under water e g water on the roof of a flat roof is not pos...

Page 5: ...able LAPP Universal Strip Solar Item number 21920120 EPIC SOLAR Mounting Tool is not necessary Two 19 mm open end wrenches are enough Crimping Tool Note To comply the tested quality it s necessary to...

Page 6: ...male Connector field mountable including Contacts 44428236 EPIC SOLAR 4PLUS F 4 mm 6 mm 4 6 5 2 7 1 8 30 44428238 EPIC SOLAR 4PLUS F 10 mm 10 5 2 7 1 12 30 EPIC SOLAR 4PLUS Male Connector field mounta...

Page 7: ...pletely into the crimp area of the contact The cable is pushed forward until the insulation strikes the crimp receptacle of the contact In this way the supermatent is insured at least 2 mm Completely...

Page 8: ...erly engaged Turn cap nut hand tight 4 5 Nm finished Spanner size 19 EPIC SOLAR 4PLUS F Connecting and Disconnecting Before plugging in check the plug in area for any dirt and if necessary clean it Es...

Page 9: ...The cables must be laid firmly in the photovoltaic system securely fastened and the minimum bending radius shall not be undercut The cable shall be led out staight at least L 50 mm The bending radius...

Reviews: