11
English
M1
M3
M2
oN
oFF
M
CoRRECT PRoCEDURE oF DECoMPRESSIoN
• Insert the gun clamp (
M1
).
•
Turn the key (
M2
) to the
oFF
(0)
position to stop the equip-
ment.
WARNING
:
If the equipment is still under pressure after performing the operations above described
because of the nozzle or the flexible hose clogged, proceed as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product and press the trigger to release
pressure.
•
Loosen very slowly the fitting of connection from the flexible hose to the gun.
• Clean or replace the flexible hose and the nozzle.
•
Open the drain valve (
M3
) to release the residual pressure
always clockwise.