Ed. 003 - 02/2013
• Use pointed pliers (
P81
) to remove the elastic ring (
P82
).
Then, completely loose the screw (
P83
) and remove it from
the bushing (
P84
).
• The gasket (
P86
) is placed inside the bushing (
P85
). Use a
suitable tool to remove the worn gasket and replae it with a
new spare one (
P87
).
At this point the procedure for the bushing gasket replacement is
completed.
Reassemble the gun following the previous procedure
in reverse order.
REPLACE THE PRODUCT HOUSE GASKET
ATTENTION
:
for further details, please refer to the drawing on page 22
To replace the product house gasket, porceed as follows:
• Remove the screw (
P88
) of the house supporting bracket by
using the suitable wrench (
P89
).
• Remove the revolving fitting (
P90
).
• Use a suitable wrench (
P93
) to loose the hex nut (
P92
) and
then remove the product house (
P91
).
www.larius.com