sirio
Ediz. 006 - 12/2017
www.larius.eu
24
K
MANUAL reseT OF THe pNeUMATIC MOTOr
•
The feed air pressure of the pump must never be higher
than the maximum value indicated in the technical data.
Exceed this value can block the valves of the pneumatic
motor in the intermediate position of the cycle reversal.
• To start again a blocked motor, close the air supply and
release pressure in the plant. This operation should allow
the recovery of the valves.
• In case the motor is blocked, proceed as follows:
- Close the air supply to the pump and release the residual
pressure in the plant;
- unscrew the motor cap (
K1
) and pull it upward along
with the guide rod (
K2
) so as to manually trigger the stroke
inversion unit;
- screw again the plug.
Necessary tools and equipment
procedure
1.1
Reassemble the high pressure filter unit
on the pump
1
K1
K2
Summary of Contents for Sirio 27:1
Page 1: ...ITALIANO Ediz 006 12 2017 www larius eu INSTRUCTION MANUAL Sirio 27 1 32 1 ...
Page 4: ...sirio Ediz 006 12 2017 www larius eu 4 White page intentionally ...
Page 9: ...sirio Ediz 006 12 2017 www larius eu 9 18 3 1 9 7 8 10 6 2 air 5 16 13 12 11 ...
Page 34: ...sirio Ediz 006 12 2017 www larius eu 34 White page intentionally ...