ROUTINE MAINTENANCE
•
Check that all the hose connections are tight.
•
Clean and, if necessary, replace the worn seals.
•
Check filters (
I1
), (
I2
) and (
I3
) and replace them when ne-
cessary.
•
Check the nozzle on the spray gun and clean it.
•
With the spray gun over the thinner tank, press the trigger
in order to let the thinner circulate during at least five minu-
tes.
•
If necessary change the thinner and repeat this operation
more times until all the residues of the product will have been
eliminated.
•
Clean the product hose (
H7
) by means of a rag and wash
the filters (
H8
), (
H9
) and (
H10
) with the solvent.
•
After the use of products with a base of polyvinyl alcohol or
of water soluble products, first clean the pump with water
and then let some alcohol circulate through the plant.
If it is foreseen a long period of standstill for
the pump, after the cleaninng let some light
mineral oil circulate in order to protect it against
corrosion.