ZEUS
17
English
MIN
MAX
PRESSIONE
PRESSURE
•
Reduce pressure to the minimum
(turn counterclockwise the
pressure control knob
(
H1
)
)
.
•
Press the switch (
H2
) “
OFF
(0)”
placed on the box of the
electric motor, to stop the equipment.
•
Hold the spray gun trigger down.
•
Open the recirculation - safety valve (
H3
) to release the
pressure in the circuit.
•
Lift the suction hose and replace the bucket containing the
product with a bucket of cleaning liquid
(make sure it is com-
patible with the product you are using)
.
•
Unscrew the nozzle on the spray gun
(remember to clean it
with cleaning liquid)
.
•
Press the switch (
H2
) “
ON”
(I)
of the equipment.
H1
H2
OFF
ON
H2
H3
Open