ZEUS
18
MIN
MAX
English
•
Turn the pressure setting knob (
H1
) clockwise to the “CIR-
CULATION & WASHING” position
(drop symbol)
.
•
Make sure that the product circulates through the circulation
hose.
•
Close the recirculation - safety valve (
H3
).
•
Point the spray gun (
H4
) into the container (
H5
) used to
collect the cleaning liquid and hold the trigger down to expel
any product remaining, until clean liquid flows out.
Now, release the trigger.
Use a metal container (H5).
To avoid any risk of electric shock connect the
collection container to a surface that is earthed
(e.g. concrete)
and not to surfaces that will insulate
the container from the earth.
Hold the spray gun against the edge of the metal
contained (H5).
Make sure that the machine sucks in clean washing
liquid. Allow the cleaning liquid to discharge into
another container and do not mix it with the cleaning
liquid still to be used.
We recommend circulating the cleaning liquid for
at least 15 minutes.
For disposing of the washing liquid, see the re-
quirements laid down in the Standards in force in
the country in which the equipment is used and
act accordingly.
The Client is solely responsible for any irregular
action taken before, during, or after disposing of
washing liquid, or in interpreting and applying the
current Standards in this regard.
Circulation
and washing
H1
Chiuso
PRESSIONE
PRESSURE
H3
Closed
H4
H5