ZEUS
19
English
MIN
MAX
H1
PRESSIONE
PRESSURE
Circulation
and washing
•
Lift the suction hose and remove the bucket of cleaning liquid.
•
Now point the spray gun (
H4
) into the container (
H5
) and
press the trigger to recover any cleaning liquid left.
•
In case of long storage, we recommend you to suck and to
leave light mineral oil inside the pumping group and the flexible
hose.
Follow the washing procedure before using again
the equipment.
• Take the cleaning liquid and store it in suitable containers.
Make sure that the machine sucks in clean washing
liquid. Allow the cleaning liquid to discharge into
another container and do not mix it with the cleaning
liquid still to be used.
We recommend circulating the cleaning liquid for
at least 15 minutes.
•
As the pump idles, press the
“
OFF”
(0)
switch (H2) to stop
the tooling.
CLEANING FOR WATER-BASED PRODUCTS
•
Reduce pressure to the minimum
(turn counterclockwise the
pressure control knob
(
H1
)
)
.
Make sure that the electrical system is earthed and
complies with regulations.
H2
OFF
H4
H5