LT-3100S GMDSS User & Installation Manual Rev. 1.02
Using the system
Lars Thrane A/S
www.thrane.eu
Page 48 of 71
NOTE
:
Alerts of priority caution cannot be acknowledged and therefore cannot have their
responsibility transferred.
The alert text and alert description of an alert is presented on the CAM system. For some alerts, additional
information must be presented in order to allow user acknowledgement of the alert. Responsibility transfer
is not allowed for such alerts as they can only be acknowledged at the alert source, where the additional
information is present.
NOTE
:
The LT-3100S GMDSS system currently does not define any alerts that allow responsibility
transfer.
Revaluation
To reduce the number of high-priority audible alerts for one situation that requires attention, if the CAM
system has additional knowledge regarding an alert situation, which caused the LT-3100S GMDSS system to
raise an alert, the CAM system may apply responsibility transfer and apply revaluation by raising a new
alert with, if practicable, a lower priority.
NOTE
:
The LT-3100S GMDSS system currently does not define any alerts that allow responsibility
transfer and revaluation.
Time synchronization
The LT-3100S GMDSS system can supply the UTC time of alert state changes to the CAM system due to the
built-in GNSS receiver.
NOTE
:
If the alert state change occurs before the built-in GNSS receiver has obtained the UTC time
or in case of GNSS receiver malfunctioning, the LT-3100S GMDSS system will not supply the
UTC time.
Printing
If the LT-3160S Printer Adapter has been installed, the LT-3100S GMDSS system can be configured to
automatically print MSI and/or priority messages on the printer.
The LT-3100S GMDSS system can print the International Reference Alphabet (IRA) character set (also
known as IA5 or T.50).