Alarm Relay
Access-T 1500 provides form C relays for each power supply to drive external
alarm annunciation devices, such as bells or lights. The larm Relay is activated
whenever a power supply loses power.
The Alarm Relay is “dry” (i.e., does not carry current from Acess-T 1500).
Therefore, any annunciation device connected to either relay must be externally
powered. The relays support both normally open and normally closed circuits
for the annunciation devices.
Alarm Relay connections are made to the ALARM RELAY connector on the
Access-T 1500 rear panel. Pinouts for the
ALARM RELAY
are shown in Figure
3-17. Make connections to annunciation devices as follows:
1.
For each power supply, insert the annunciator leads into the appro-
priate connector plug openings (NO and C for a normally open
circuit, or NC and C for a normally closed circuit). Then tighten the
corresponding screws on the top of the connector plug until the leads
are secured to the plug.
2.
Mate the connector plug with the
PS1
or
PS2
alarm relay socket on the
Access-T 1500 rear panel.
3.
Provide strain relief by installing the strain relief bracket on the rear
panel.
Figure 3-17. Alarm Relay Connections
ALARM RELAY
NC
NO
GDN
C
NC
NO
GDN
C
PS2
PS1
ACST-0351-005
Chapter 3
June 1996
Installation