3-54
3.4 Control Circuit Connections:
system of ACB’s Secondary Isolating
Contacts (8b) facilitate Control circuit wiring with
following features,
—
Cradle SIC block slot & each breaker SIC slot is
pre-defined and marked for specific connections
(Ref. page 3-37).
—
Breaker is supplied with SIC as per the order
configuration.
—
Every accessory comes pre-wired with breaker
SICs .SIC location is printed on the wire for easy
identification.
—
Breaker SIC are click-fitted and hence, require no
tools for fixing. Cradle SIC block is mounted with a
screw driver.
—
SICs offer screwless wire connections, by simply
using a connector as shown in the diagram.
—
SICs can independently accept 2 wires for ease of
terminating multiple wires. Wire specifications:
2
2
Min 0.75 mm & Max 2.5 mm .
—
After termination, control wires can be routed
through guides provided in the cradle side plates.
Electrical Position Indication (EPI):
1
2
3
5
7
8
6
4
Connected
Test
Disconnected
Routing Control wires
1 All position SIC
2 Connected & Test position SIC
3 Connected position SIC
4 Additional Connected position indication
5 Test position SIC
6 Additional Test position indication
7 Disconnected position SIC
8 Additional Disconnected position indication
Quick and Easy Control wiring
Strip Conductors
SICs & SIC Bridge
CAUTION
Lugs to be used with wires getting inserted into
SIC. Do not use wires without lugs.
Wire bunch to be routed properly to avoid
interference with Door Interlock (40), if installed.
Tip width 3 mm
Ensure lug orientation
with serrations on top
8mm
Summary of Contents for U-POWER Omega UW-MTX 1.5G
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ......
Page 8: ......
Page 10: ......
Page 12: ...Microswitch...
Page 15: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 27: ......
Page 30: ...3 12 X X 100 150 mm X 100 150 mm X X 15 max...
Page 45: ...3 27 Termination Draw out Breakers THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 46: ...Termination Draw out Breakers 3 28 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 71: ...3 53...
Page 83: ...4 1 4 1 Cradle Mounted Accessories...
Page 84: ...4 2...
Page 85: ...4 3...
Page 86: ...4 4...
Page 87: ...4 5...
Page 88: ...4 6...
Page 89: ...4 7...
Page 90: ...4 8 4 2 Breaker Mounted Accessories...
Page 92: ...4 10...
Page 93: ...4 11...
Page 94: ...4 12...
Page 95: ...4 13...
Page 97: ...Section 5 Protection Control units 5 1 Identification 5 2 Protection Characteristics...
Page 104: ...5 7 Protection Characteristics Overload I T for UW MTX1 0 2 0 1 1 10 100 1000 10000 10s...
Page 119: ...6 3 6 3 Testing Control circuit Interlocks if breaker is equipped with accessories...
Page 134: ......
Page 136: ...7 7...
Page 142: ...Section 8 Useful Hints...