background image

MAINTENANCE:

WARNING: It is very important that only 

qualified 

per-

sonnel perform maintenance and repair operations in a 

NON-HAZARDOUS area. The integrity of the component 

assembly and flame-path must be maintained in order 

to provide adequate protection for personnel using this 

light. Comply with all NEC Rules and Regulations when 

performing maintenance operations.  Failure to comply 

with these could result in an explosion, electrical shock, 

or personal injury.

WARNING: When performing maintenance operations 

disconnect power. Failure to do so could result in electri

-

cal shock.

Make a thorough visual inspection of the work light for any 

chips, cracks, or burns within the glass, aluminum handle, 

and cage.  Check the entire length of the cord for any frays 

or visible wires that could affect the performance of the 

light. Check that all the rubber bumpers are integral with 

the aluminum. If there are any frays in the cord, cracks in 

the glass or disturbances in the aluminum outside of nor

-

mal wear, remove the light from service immediately and 

contact 

Larson Electronics for replacement

.

CAUTION: 

Clean external parts of work light only; inter

-

nal parts do not require cleaning.  Applying solvent could 

result in damage to the electrical equipment. 

The 

EPL-FL26-LED

 can be cleaned applying Simple Green® 

or an equivalent cleanser and wiping any dust or grease off 

with a rag.  After cleaning process is performed, allow 

adequate time for light to completely dry before placing in 

operation.

INTRODUCTION

This document covers the operation, maintenance, and 

re-lamping procedures for an 

EPL-FL26-LED

 hazardous 

locations work light.  This light is suitable for the 

following hazardous locations only:

Class I, Divisions 1 & 2, Groups C & D

Class II, Divisions 1 & 2, Groups E, F,  and G

Class III, Divisions 1 & 2

Refer to the National Electric Code (NEC) NFPA 70 for 

more information on hazardous locations.

OPERATIONS AND USE

WARNING:

FOR FLYING LEADS:

 

This light is not supplied with a plug. If the light is used 

in a hazardous location environment, it must be 

terminated with a suitable plug or hard wired into an 

appropriate junction box rated for the environment it 

is to be used in.  Comply with all NEC Rules and Regu

-

lations when terminating light with a plug. Failure to 

comply with this could result in an explosion, electri

-

cal 

shock, or personal injury.

CAUTION:

 

Follow manufacturer’s instructions for attaching plug 

to light ensuring all wires are properly terminated and 

grounded.

CAUTION:

When hanging the light using the hook, use an ap

-

propriate entity capable of holding at least 6 lbs. (2.72 

kg).

EPL-FL26-LED Series

Explosion Proof Compact LED Handlamp

Instruction Manual

Larson Electronics, LLC

 

Phone: (877) 348-9680

 Fax: (903) 498-3364 

 www.larsonelectronics.com 

1

 of 

2

 

PLUG OPERATION

 (for units pre-wired with explosion proof cord cap)

Electrical connection between plug and compatible receptacle is accomplished after plug fully inserts into receptacle and is rotated 

clockwise. 

1.

Lift  receptacle  door  and  locate  polarization  on  mating  plug  pin  and

 

receptacle  face.  Insert  plug  straight  all  the

way  into  receptacle  until  it

 

cannot go further.

2.

Rotate  plug  clockwise  limit  (37º),  this  closes  internal  contacts  and

 

completes  circuit.  This  also  mechanically  locks

plug  into  receptacle  so  it

 

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

 

straight out.