Explosion Proof 300 Watt LED

 Flood

 Light

 Fixture

 

 Paint Spray Booth Approved

 

Instruction Manual

 

This explosion proof light is designed for illumination of industrial locations. It uses the latest in 
solid state lighting technology for long life, low maintenance and high efficiency. 

The unique design focuses the light where it is needed, giving improved efficiency over a 
conventional HID luminaire. 

An internal, universal input, power-factor-corrected switch-mode supply allows it to be used from 

any nominal 100-277V AC 50/60 Hz power supply without any variation in light output.

 We also 

offer a low voltage 11-25V DC version of this light fixture as an option. 

 

WARNING 

To avoid the risk of fire, explosion or electric shock, this product should be installed, inspected 
and maintained by a qualified electrician only, in accordance with all applicable electrical codes. 

To avoid electric shock: 

Be certain electrical power is OFF before and during installation and maintenance.

Luminaire must be connected to a wiring system with an equipment-grounding conductor.

To avoid explosion: 

Make sure the supply voltage is within the luminaires’ voltage rating.

Ensure the marked T rating is less than the ignition temperature of the Hazardous
Atmosphere.

Do not operate in ambient temperatures above those indicated on the luminaire nameplate.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

For supply connections, use wire rated for at least 110°
C Recommended mounting height is 

1

5-40 feet. 

MOUNTING

 

This fixture offers an adjustable

 swivel

 mounting system that allows it to be mounted to any 

flat surface including walls and ceilings. Three heavy duty bolts are used to mount the fixture to the 
surface through pre

-

drilled holes on mount. Hole diameter is .563”. Fixture is heavy - two people and 

capable equipment are required for hanging fixture. 

An optional pendant mount is also included with 

this fixture, which screws into the 3/4'' NPT hub on the back of the fixture. 

Fixture angle can be adjusted by loosening the set screws on either side of mount. Swap outer bolts 
to move mount in opposite direction. Keep center bolt in place! Otherwise fixture will free from 
mount. 

Use appropriate wiring methods for the area following all NEC, local, and state electrical codes. 
Conduit attaches to the junction box on the back for wiring. 

ADJUSTMENT BOLTs 

CENTER BOLT 

ONLY LOOSEN

DO NOT REMOVE COMPLETELY 

WHILE MOUNTED TO SURFACE

 