background image

 

 

When starting the flashlight for the first time (cold start), it is recommended that user allows HID to 
power up to full (40-60 seconds) before powering off again. This allows the lamp time to achieve a 
temperature hot enough to vaporize the additives and prevent deposits from forming on the inner arc 
chamber walls. When powering up, it is normal for the lamp to “flicker”, this is the result of the metal 
salts in the arc chamber vaporizing. You will also see a slight shade of red and blue. As the light comes 
to temperature the flickering will subside, the arc will stabilize and the light output will increase. The 
Light emitted from the flashlight is a higher Kelvin temperature (blue in color) than ordinary flashlights. 
Full light output occurs in 10-15 seconds. If momentary shut off of the light is needed you can instantly 
restart the light without worry of damage or cool down. It is suggested not to “flash” the light, as this 
will shorten run time and lamp life. 

CHARGING THE FLASHLIGHT 

1. Before charging, power off the HID flashlight. It is to remain powered off while charging.
2. Charger stand required to charge EP batteries. Open the rubber waterproof cover located at the

bottom of the light (on end cap), connect the male jack of charger to the female receptacle of
the flashlight.

CAUTION:

 

Use only the supplied flashlight chargers; do not use other chargers as this will cause

battery failure, overheating and possibly explosion.

3. Connect the charger plug to AC wall power or the DC power source (if DC charger is being used).
4. Charging time will be approximately 2.5 hours.
5. When the charge is complete, (indicated by Green LED), unplug the charger from the power

source and disconnect the battery jack from the flashlight. Replace the rubber cap of the female
receptor (on end cap) to prevent water from seeping in.

6. The optional Battery Charger Stand may be used to charge a spare Lithium Battery with either

the AC or DC battery chargers.

NOTE: 

When charging for long periods of time, the charger and battery will get hot. This is normal. If 

excessive heat or odor is noticed, disconnect the charger immediately. 

 

The charger uses a 2-color LED indicator (Red and Green): 

When connecting power, the LED will illuminate 

Green

.

While charging, the LED will illuminate 

Red

.

When fully charged, the LED will again illuminate 

Green

.

Do not leave the light or battery on charger past full charge or the overcharge circuit protection will 
activate.  

Please refer to “

Battery Charging

 Notice” section, if light fails to ignite after a full recharge. 

EPL-UV-20W-G2

Explosion Proof Black Light - 365nm UV Cut Off Lens  

C1D1

&2

 & C2D1

&2

 - Gen 2

Instruction Manual

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

1

 

of 3

 

Reviews: