HAL-48-33W-LED-1227-70C
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
1
of
2
40W Low Voltage LED Fixture for Hazardous Location Lighting
C1D2 - 70' 16/3 SOOW Cord
Instruction Manual
Thank you for your purchase of the Larson Electronics
HAL-48-33W-LED-1227-70C
.
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
•
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
•
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF
FIXTURE'S
ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
•
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
•
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE
FIXTURE'S
RATED VOLTAGE.
•
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. THE
HAL-48-33W-LED-1227-70C
MUST BE WIRED IN ACCORDANCE WITH NATIONAL
ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS PRODUCT.
IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET, CONSULT AN
ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING:
MAKE SURE POWER IS TURNED
OFF
BEFORE STARTING THE
INSTALLATION OR PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –
DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.
RISK
OF PERSONAL INJURY –
FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY.
RISK
OF BURN –
ALLOW FIXTURE TO COOL BEFORE SERVICING.
WARNING:
USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE.
THIS LINE
CORD IS INTENDED TO ALLOW OPERATORS TO EXTEND POWER TO EQUIPMENT WHEN STATIONARY OUTLETS ARE NOT
READILY AVAILABLE.
IMPROPER USE OF THIS CORD, PLUG, AND RECEPTACLE CAN LEAD TO SERIOUS INJURIES OR DEATH TO
PERSONNEL.
PERIODIC INSPECTION OF THE CORD IS NECESSARY.
THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND,
THE CORD MUST BE REPLACED BEFORE RESUMING USE.
The Larson Electronics HAL-48-33W-LED-1227-70C Low Voltage LED Fixture is a powerful hazardous location lighting solution for
Class I, Division 2 environments and wet locations. This powerful 46.88" long LED strip light produces 5000 lumens, operates from
120-277V AC 50/60 Hz DC and is suitable for a variety of applications. Equipped with 70` of 16/3 SOOW cord, the unit contains triangle-
end brackets for mounting.
WIRING
Standard pigtail(flying leads) wiring
We strongly encourage a licensed electrician install this product
, in all locations especially in outdoor areas where
weatherproofing may be required. Universal voltage driver permits operation at 100V - 277V AC, 50 or 60Hz except those factory
ordered with low voltage 11V to 25V AC/DC.
Warning:
Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown in the diagram
Secure each pair of wires according to the diagram. Utilize a junction box or similar device and
take precautionary steps for weatherproofing all connections if installed in a location where
water may come in contact with the unit. Ensure the unit is properly grounded and that wiring is done
according to all local and national electrical/building codes.