IND-LP-SS-24-2X2-2L-UVC
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
2
of
3
WIRING
Power connections to the UV unit can be completed via two accessible, threaded wiring hubs (1/2" or 3/4").
Standard pigtail(flying leads) wiring
We strongly encourage a licensed electrician install this product
, in all locations especially in outdoor
areas where weatherproofing may be required. Universal voltage driver permits operation at
120-277V AC, 50/60 Hz
.
Warning:
Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown in the
diagram
Secure each pair of wires according to the diagram. Utilize a junction box or
similar device and take precautionary steps for weatherproofing all
connections if installed in a location where water may come in contact with the unit.
Ensure the unit is properly grounded and that wiring is done according to all local and
national electrical/building codes.
MOUNTING
The IND-LP-SS-24-2X2-2L-UVC features a surface mounting system. Surface mounting brackets on the housing facilitate a low profile wall
or ceiling mount, making it suitable for installations in tight spaces.
B
U
LB
REP
L
A
C
EMENT
Warning:
Do not touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced
performance and significantly reduce the lifespan of the lamp unless removed with alcohol. Be sure fixture is disconnected from
power source and cooled off before servicing.
To replace a bulb in your
fixture
, you must first remove the
fixture
from power
.
Before removing the bulbs, it is recommended to
remove the fixture from its mount.
Remove the bulb to be replaced by grabbing the ends and pressing either up or down against one
of the spring loaded bulb receptacles. This will free the other end and allow you to remove the bulb. Replace the bulb with one of the
same type and rating. Install the new bulb by aligning the 2-pin connector with the slots in the bulb receptacle at the bottom. Press the
bulb down against the spring loaded receptacle to create room at the top, and align the two top pins on the bulb with the top
receptacle and release. Repeat this process for any remaining bulbs that need to be replaced.
After ensuring proper operation,
m
ount
the fixture back to the desired location if applicable, connect the fixture to power, and continue use.
MAINTENANCE
Caution:
To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing maintenance.
Warning:
No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void the warranty.
1.
Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine
checks to be made on a yearly
basis. Frequency of use and environment should determine this. It is
recommended to follow an Electrical Preventive
Maintenance Program as described in NFPA 70B:
Recommended practice for Electrical Equipment.
2.
The lens should be cleaned periodically as needed to ensure continued photometric performance.
Clean the lens with a damp,
non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid
cleaner.
3.
Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or
contamination (i.e. excessive dust
build-up). Clean with a non-abrasive cloth if needed.
4.
Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.
USE AND CARE
Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. Always
check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of children when not in use.
Inspect for good working condition prior to storage and before re-use.
REPLACEMENT PARTS
The
IND-LP-SS-24-2X2-2L-UVC
is designed to provide years of reliable performance. Should the need for replacement parts arise,
please contact Larson Electronics.
THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS.
SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT
SALES@LARSONELECTRONICS.COM
OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.
PLEASE VISIT LARSONELECTRONICS.COM FOR
WARRANTY
AND
RETURN