4.0 Lowering Mast:
4.
1.)
T
o lower the mast you first turn the
COMPRESSOR switch to the OFF position
,
and
the MAST switch to the LOWER position to
begin lowering.
NOTE:
This process takes at least 10 minutes to
fully lower.
4.2.)
Once fully lowered, take out the
mast safety pin. This will allow you to
fold
the
mast down
horizontally to its transport position
.
4.3.)
After the safety pin is removed, press
and hold the HYDRAULIC RAM DOWN
button to lower the mast back down to its original
position.
4.4.)
When the mast is in its original
position, you may now turn off all breakers in
the breaker box above the control panel.
4.5.)
After turning the breakers off,
press
the
GENERATOR STOP button
and turn
the generator breaker off.
NOTE: The generator
must run for 5 minutes without a load before
turning off.