MOTION SENSOR
Operating voltage
Rated load
HF system
5.8GHz±75MHz, ISM wave band
Transmitting power <0.5mW
Power consumption
≤
0.5W(standby)
Detection zone
Max.(D x H): 16m x 15m
Detection sensitivity
/
/
/ 50%
10
%
%
%
%
%
%
Hold time
5s /
45
s /
5
min
/
15
min
Daylight sensor
2
Lux/
10
Lux
/
30
Lux
/Disable
Mounting height
15m Max.
Motion detection
0.5~3m/s
Detection angle
150°(wall installation)
360°(ceiling installation)
Operating temperature
-25
℃
~60
℃
IP rating
IP20
Setting
ON
ON
ON
ON
ON ON
ON
ON
ON
ON
ON
I
II
III
IV
1 2
10%
5
0
%
7
5%
100
%
I
II
III
IV
3 4
5s
45
s
5
min
15
min
I
II
1
0
lux
2
lux
30lux
III
IV
By selecting the combination on the DIP switch, sensor data can be precisely set for each specific application.
ON
ON
D
Detection Area
Detection area can be reduced by selecting the combination on the
DIP switches to fit precisely each application.
H
Hold Time
Refers to the time period the lamp remains at 100% illumination after
no motion detected.
D
Daylight Sensor
The sensor can be set to only allow the lamp to illuminate below a
defined ambient brightness threshold.
When set to Disable mode, the daylight sensor will switch on the lamp
when motion is detected regardless of ambient light level.
30lux:twilight operation, 2lux, 10lux: darkness operation only.
D
isable
O
ON
N
ON
5 6