1660K073H
Page 7 of 28
Parameter 9: RS-485 configuration. This parameter is shown if the display includes RS-485 option:
Access this parameter pressing the Advance key. Change the code according to the desired configuration.
Code
Baud Rate
Data bits
Parity
Stop bits
01
4800 Bauds
7 bits
No parity
1
02
9600 Bauds
7 bits
No parity
1
03
19200 Bauds
7 bits
No parity
1
04
4800 Bauds
8 bits
No parity
1
05
9600 Bauds
8 bits
No parity
1
06
19200 Bauds
8 bits
No parity
1
07
4800 Bauds
7 bits
Even
1
08
9600 Bauds
7 bits
Even
1
09
19200 Bauds
7 bits
Even
1
10
4800 Bauds
8 bits
Even
1
11
9600 Bauds
8 bits
Even
1
12
19200 Bauds
8 bits
Even
1
13
4800 Bauds
7 bits
Odd
1
14
9600 Bauds
7 bits
Odd
1
15
19200 Bauds
7 bits
Odd
1
16
4800 Bauds
8 bits
Odd
1
17
9600 Bauds
8 bits
Odd
1
18
19200 Bauds
8 bits
Odd
1
19
4800 Bauds
7 bits
No parity
2
20
9600 Bauds
7 bits
No parity
2
21
19200 Bauds
7 bits
No parity
2
22
4800 Bauds
8 bits
No parity
2
23
9600 Bauds
8 bits
No parity
2
24
19200 Bauds
8 bits
No parity
2
25
4800 Bauds
7 bits
Even
2
26
9600 Bauds
7 bits
Even
2
27
19200 Bauds
7 bits
Even
2
28
4800 Bauds
8 bits
Even
2
29
9600 Bauds
8 bits
Even
2
30
19200 Bauds
8 bits
Even
2
31
4800 Bauds
7 bits
Odd
2
32
9600 Bauds
7 bits
Odd
2
33
19200 Bauds
7 bits
Odd
2
34
4800 Bauds
8 bits
Odd
2
35
9600 Bauds
8 bits
Odd
2
36
19200 Bauds
8 bits
Odd
2
Once the serial line is configured, press the Enter key to modify the display address. This must be between 01
and 99. If the user presses the Enter key again, the End of Block can be modified. This can be:
Code
End of block
0
0Dh
1
0Ah
2
0Dh 0Ah
3
0Ah 0Dh
4
2Ah 0Dh
5
02h
6
03h
7
04h
Press the Enter key to go back to the menu.