4-6
OPERATION
CHAPTER 4
Display series DN-107P
4.2.5.7.
Parameter 8. S2: Activation and temporization conditions of output 2
See 4.4.2
“Using functions counter or chronometer”
4.2.5.8.
Parameter B. So: Exit modify parameters.
In order to exit the sequence for modifying parameters, select the last parameter in the
menu. Then press "*".
See the input wiring and examples in 4.3.6
4.2.6.
Parameters of functions 05, 15 and 25 (Tachymeter).
Parameter 2. FE: input frequency
Parameter 3. dt:
display’s value.
Parameter 4. EL: updating time.
Parameter 5. Ll: Limit time without impulses.
Parameter 6. Pd: number of decimals.
Parameter 7. FA: mortifying factor.
Parameter F. in: Exits programming.
4.2.6.1.
Parameter 2.FE: Input frequency.
Adjusts the value of the input frequency according to the following table:
Number of
digits
Maximum frequency
Minimum frequency
3
999
0,01
4
9999
0,001
The decimal point is selected with the increase key (+) after programming the frequency
4.2.6.2.
Parameter 3.dI: Value of the display.
Selects the number shown when the frequency is equal to the input frequency of
parameter 2.
Number of
digits
Maximum value
Minimum value
3
999
0,01
4
9999
0,001
The decimal point is selected with the increase key (+ ) after programming the
frequency
4.2.6.3.
Parameter 4.EL: Updating time
Selects the updating time of the display. The time is measured in tenths of seconds and
the rank is between 1 and 199 (0.1s and 19.9s).
With a big updating time there will be less changes on the frequency shown by the
display. If the input frequency is un
stable, select a big updating time to reduce the display’s
changes.
4.2.6.4.
Parameter 5.LI: Time without pulses limit.
Adjust the maximum time between two impulses. If this time is surpassed, the display
shows 0. The time is measured in seconds and the rank is between 1s and 99s