1706K45B
Page 2 of 27
Installation of the DR-129
336
1220
120
85
40
40
67
9
9
8 x ø 5
All dimensions are in millimetres
Powering the display
The power supply must be 88 to 264VAC, 47 to 63 Hz.
The power supply conductor section will be in line with consumption and the ground conductor will be
a minimum section of 1.5m².
The power supply connector for 220VAC has 4 contacts and is situated in the lower part of the unit.
Connect the power wires following the schema below
DR-129 characteristics.
Power supply ............................................... 88 to 264VAC, 47 to 63 Hz
Consumption ................................................ 35VA
Display .......................................................... 4 digits 7segments 250mm two central dots. Red LED.
....................................................................... Visibility 120 meters.
Environmental conditions .......................... Operating temperature: -10 to 60ºC.
....................................................................... Storage temperature: -20ºC to 70ºC
....................................................................... Relative humidity: 5-95% non-condensation.
....................................................................... Maximum environmental lighting: 1000 lux.
....................................................................... Protection IP 41 or IP54.
Weight ........................................................... 12 Kg.