Cod. 40115 | Rev. 19 | 05/2021
APOLLO 15. ORION 13, SIRIUS 11:
air fireplaces with front glass
(1) AIR ENTRY IN THE COATING
: it is obligatory to always ensure a
minimum ventilation inlet and outlet in the coating through a grid at the
bottom and a grid above (decompression) of
at least 450 cm2 each
.
They can be done frontally, laterally or even later, provided that the
circle of air entering and leaving is always inside the house (and not
outside).
(2) INSPECTION DOOR:
to load the
pellets
into
the
tank,
periodic
maintenance as well as annual cleaning
of the chimney flue, spare parts, it is
mandatory to leave the electronic
components on the side (as standard to
right, looking at the chimney from the
front) a sufficient inspection door to
access all the components of
at least
50x140
cm in height.
(3) HOT AIR FAN SIDE CHANNEL:
the
appliance is supplied with a lateral centrifugal fan of 160 m3 / h with a
hot air outlet of Ø 80 mm to channel (maximum distance of 6 meters).
The fan can be managed by remote control client (VENT-3) from
speed 0 (stop) to 5 (max) or automatic. For optimal installation, we
recommend using thermally and acoustically insulated pipes to ensure
the best acoustic and thermal comfort.
(4) HIGHER PIPING OF THE HOT AIR FAN:
the unit is supplied with
a tangential rear fan of 260 m3 / h which pushes the hot air towards
two top Ø 80 mm which must be ducted on the hood up to a maximum
distance of 1.5 meters. The fan is not manageable by the customer
but starts automatically when the device is at temperature and is
automatically adjusted according to the combustion power.
Refer to the following diagram to make the correct connections for the
upper air connections. The hot air from the tangential fan comes out
of the two "A" nozzles Ø 80 mm: they must be connected to the hood
at a maximum distance of 1.5 meters. Two "B" entries of Ø 150 mm
come out of natural convection hot air (not forced): they must remain
free, the hot air will then come out of the decompression grid provided
at the top of the coating or better yet, connect a piece of aluminum
pipe to it and connect it to dedicated vents or direct them towards the
decompression grid provided at the top of the cladding.
Only for APOLLO 15 and ORION 13 models, a PLUS ventilation kit is
OPTIONALLY
supplied for mounting on the unit instead of the "B" air
collars. In this case, the device will be equipped with 2 other
centrifugal fans above 180 m3 / h with an air outlet of Ø 60 mm which
must be channeled to a maximum distance of 5 meters. The fans can
be fixed at different angles to choose the most favorable position for
the pipe. The fans will run in parallel and will be managed by remote
control client (VENT-2) from speed 0 (stop) to 5 (max) or automatic.
For optimal installation, we recommend using thermally and
acoustically insulated pipes to ensure the best acoustic and thermal
comfort.
SUPERIOR DEFLECTORS
Each appliance can have smoke deflectors (in vermiculite) to be
placed in the upper part of the combustion chamber.
The models with front glass (APOLLO 15, ORION 13 and SIRIUS 11)
have this type of deflector: