Warning: it is important to check the compatibility
with the device working of any mechanical suction
blower (VMC, such as kitchen-hoods) present in the
environment. The recommended depression should be
checked carefully to avoid placing too much negative
pressure in the room, and then generate a bad working
of the pellet unit. In this case, provide a supply of extra
air.
15. TECHNICAL FEATURES
A = Main pellet tank, capacity 30 kg. (See CHAPTER 16)
B = Burner unit . (See CHAPTER 17)
C = Electric box. (See CHAPTER 18)
D = Inlet Ø 80 mm primary combustion air,
only for wood chimney
use
. (See CHAPTER 20)
E = Natural flue gas duct (no smoke extractor) Ø 200 mm, optimum
draft 12 pascal. (See Chapter 12)
F = N ° 2 Air heating fans, Ø 80 mm pipe connection, can be ducted
up to max. 5 meters. (See CHAPTER 21)
G = No. 3 stainless steel deflectors (See CHAPTER 22)
H = Convection air inlet for heating. (See CHAPTER 21)
I = Sliding three-faced door. (See CHAPTER 23)
L = Removable brazier grill. (See CHAPTER 24)
M = Closure pellet bracket and wood grid. (See Chapter 25)
16. MAIN PELLET LOAD TANK
The top main tank has a capacity of about 30 kg pellets (in the course
of 2018 it will be increased to about 65 kg).
The opening of the sliding door for pellet loading is on the right side
(looking at the fireplace in front). However, the loading slide can be
moved from the other side by unscrewing the screws that secure it
and inverting it with the fixed cover on the other side.
WARNING: The pellet loading door must remain
closed when operating the appliance.
The use of the appliance with the open door is
prohibited as it alters all combustion values.
If the appliance emits an intermittent beep, it means
that photocell 1 detects pellet shortage in the main tank.
Proceed therefore to pellet refill.
FUEL LOADING
To load the pellet into the tank it is advisable to cut a corner of the bag
and empty it slowly into the tank. Make sure there are no foreign
objects in the bag.
WARNING: It is forbidden to leave the pellet on the
hot parts of the appliance especially on the top cover,
FIRE WARNING. During loading, make sure that the
plastic bag / paper does not come into contact with the
hot areas of the appliance. Do not overfill the tank with
the risk of leakage of the pellet.
Pellet is packed in plastic or paper bags. Do carefully stock it to allow
humidity from damaging it..
17. BURNER GROUP
The burner unit is the heart of this appliance. Below is shown the
positioning of the 2 tanks and the 3 new generation photocells that
manage the pellet charge operation. On the next page, the schema of
all components.
WARNING: Use of low quality fuel, very dusty, or
smoke returning for bad drafting of the chimney, may
Summary of Contents for Pellicano M14
Page 14: ...L ARTISTICO SRL IT 14 Cod 40014 Rev 04 08 06 2018 32 SCHEMA ELETTRICO ...
Page 16: ...L ARTISTICO SRL EN 16 Cod 40014 Rev 04 08 06 2018 ...
Page 29: ...L ARTISTICO SRL EN 29 Cod 40014 Rev 04 08 06 2018 32 ELECTRICAL DIAGRAM ...
Page 31: ...L ARTISTICO SRL 31 Cod 40115 Rev 04 08 06 2018 ...