Unpack and visually check all the components, making sure that there are no oil leaks, loose or damaged plugs, damaged threads, etc. Never 
use components that are damaged or appear to be in poor condition.  
 

 

Assemble the device in accordance with the instructions given in the diagram, first checking that you have all the necessary material. 

 

 

Check the correct installation and perfect functioning of the device with a load, in accordance with the procedure outlined below: 

 

SINGLE ACTING INSTALLATION 

 
1. 

Place the distributor valve in central position. 

2. 

Pump manually; with the oil filling plug opened, several times to allow the entry of air in the pump and make easier the suction  

3. 

Close the plug by turning clockwise manually. You do not need to close too tightly. 

4. 

Place the distributor valve in advance position and pump using the drive lever. First, fill the hose with oil. The number of strokes required will 
depend on the length of the hose and the flow supplied by the pump piston. With two-speed pumps, the large piston will be activated during 
the  load-free  feed  movement,  and  when  the  device  comes  into  contact  with  the  load,  an  internal  large  piston  relief  value  will  be 
automatically triggered and only the oil supplied by the small piston will be available up to 700 kg/cm

2

, which is the maximum pressure for 

the device.  

5. 

Once the hose is full of oil, the cylinder piston will start to advance.  

6. 

If the cylinder has a mechanical limit switch capable of withstanding the maximum device pressure, continue pumping until the limit switch is 
reached.  

7. 

If any control elements (pressure gauges) are available, you will be able to see how the pressure increases along with the effort required 
moving the lever.  

8. 

Keep  pumping  until  you  obtain  the  maximum  pressure  (700  kg/cm

2

).  In  this  way  you  will  be  able  to  check  the  correct  functioning  of  the 

internal safety valve and the absence of oil leaks in the installation.  

9. 

Maintain pressure  in the  installation  for  a  short  period  of time  (1 minute)  without  pumping  (central  position),  in order  to  check the  correct 
functioning of the pump’s check valve.  

10.  To retract the cylinder, place the distributor valve in return movement. If the cylinder has a return spring (SM, SMP, SMX, SH, TE, T, SAM, 

SAH,  SATM,  CY,  KC)  the  piston  will  move  back  automatically.  The  return  speed  may  be  slow  in  some  applications.  In  this  case,  we 
recommend the  use  of  double effect cylinders. In  the  case  of  load return  cylinders  (SP, SPR,  SX,SL,  SSR,  ST, STR,STX,  SAT),  you  will 
need to push the piston back using more or less force, depending on the size and position of the cylinder. 

11.  In cylinders without a mechanical limit switch (SSR, ST, STR, STX) this type of test cannot be carried out. If you do not have a test bench, 

you  will  have  to  test  the  installation  using  the  actual  load  in  the  application.  This  operation  should  be  carried  out  with  extreme  care  by 
experienced personnel and maximum safety measures should be applied.  

12.  Repeat the process as many times as necessary until you is comfortable handling the device. 
13.  If using close or check valves, or working with various cylinders via flow distributors, remember to take into consideration the effect these 

accessories may have on the functioning of the device, and establish an operating procedure in order to avoid unwanted effects.  

 

DOUBLE ACTING INSTALLATION 

 

1. 

The  connection  of  the  couplers  is,  if  possible,  even  more  important  here,  since  a  bad  connection  will  not  only  prevent  the  device  from 
functioning, it may also generate excessive pressure build-up that may cause the break of the cylinder. Take note of which hose connects to 
the advance chamber and which to the return chamber. 

2. 

All double action LARZEP cylinders are equipped with a mechanical  end of stroke capable of withstanding the nominal pressure. You can 
therefore carry out the test described in the previous section. If you are working with another type of cylinder and are not 100% sure, do not 
carry out this test. 

3. 

Turn the control of the distributing valve to the central position and pump and few times to fill the internal channels with oil.  

4. 

Turn the lever to one side and pump. Oil will flow through the hose connected to the side to which the valve lever is rotated. If this hose is 
connected to the cylinder’s thrust chamber, the piston will move forward. The oil in the return chamber will flow freely through the other hose 
to the pump tank. Flow is supplied by both the large and small pistons until the cylinder reaches the load. 

5. 

Continue pumping until you reach the mechanical end of stroke. At this moment an internal large piston relief value will be triggered, and 
only the oil supplied by the small piston will be available. Subject the installation to pressure to check for leaks.  

6. 

Stop pumping and check (preferably using a pressure gauge) that the installation maintains the pressure level.  

7. 

Turn the valve lever to the other side and pump. Oil will flow to the return chamber and the piston will move back. The oil in the  advance 
chamber will flow freely back to the tank.  

8. 

Repeat the processes as many times as necessary until you are comfortable handling the device. 

9. 

If using close or check valves, or working with various cylinders via flow distributors, remember to take into consideration the effect these 
accessories may have on the functioning of the device, and establish an operating procedure in order to avoid unwanted effects. 

 

5. MAINTENANCE 

 

Checking the oil level. 
 

 

With the pump in vertical position, unscrew or pry off the plug. Check the level on the dip stick. 
 

 

This check must be carried out with the cylinder fully retracted. Excessive amount of oil in the tank will lead to internal pressures which will 
hamper the function of the pump. 

 

 

Filter the oil before filling up the pump. 

 

 

Once the equipment is being used the areas exposed to wear and oxidation must be cleaned and greased. 

 
 
 

Summary of Contents for W07807

Page 1: ...oad 3 Commerce Way Leighton Buzzard 48269 MALLABIA SPAIN HALLAM VIC 3803 AUSTRALIA BEDS LU7 4RW UNITED KINGDOM Tel 34 943 171200 Tel 61 3 9796 3744 Tel 44 1525 377819 Fax 34 943 174166 Fax 61 3 9796 5964 Fax 44 1525 851990 e mail sales larzep com e mail sales larzep com au e mail sales larzep co uk www larzep com www larzep com au www larzep co uk ...

Page 2: ...nsulting the manufacturer Do not use the hoses for transporting the device Use the handles on the cylinders when appropriate and set the pump lever to the transportation position When filling the pump with oil always use LARZEP hydraulic oil or another oil of similar characteristics Fill only to the indicated level and remember that the cylinder piston should be back Before starting operation chec...

Page 3: ... cylinder hook ups where greater oil capacity is required All pumps have 3 8 18 NPT female ports The X models are automatic two speed pumps with a 4 way control valve for operation of double acting cylinders Internal pressure relief valves for overload protection Two speed operation for high tonnage cylinders where oil capacity and fast economical cycle time is needed REFERENCE SPEEDS USABLE OIL O...

Page 4: ...tion This operation should be carried out with extreme care by experienced personnel and maximum safety measures should be applied 12 Repeat the process as many times as necessary until you is comfortable handling the device 13 If using close or check valves or working with various cylinders via flow distributors remember to take into consideration the effect these accessories may have on the func...

Page 5: ...ng ball valve failure 22 ____ Clean the seat and replace the ball THE CYLINDER DOESN T REACH WORKING PRESSURE Relief valve decalibrated 12 ____ Calibrate the valve Retention ball valve failure 20 ____ Clean the seat and replace the ball Closing ball valve failure 22 ____ Clean the seat and replace the ball Pressure seal damaged 26 ____ Replace the seal Cylinder pressure seal damaged see cylinder _...

Page 6: ...6 Instruction Manual Hydraulic Hand Pump W07807 X07807 7 DECLARATION OF CONFORMITY ...

Reviews: