3
Instruction Manual
Hydrostatic Test Hand Pumps WIP0040, WAP0040
TECHNICAL FEATURES
OPERATING INSTRUCTIONS
1.
Place the equipment on a flat and solid area. Fill the tank with at least 9 litres of clean water.
2.
If possible, fill the water system with a motor pump.
3.
Connect the hose to the water system to test. Make sure that the outflow tap is closed.
4.
Set the water system to the requested pressure. To keep the water system at the requested pressure for a long
time without the pump connected, we suggest you to use HELP not given with the pump.
5.
When finishing the test, open the outflow tap and then remove the high pressure hose from the water system.
Model
Working
Pressure
Flow /
stroke
Outlet
Port
Capacity Weight
LARZEP
bar
cc
BSP
litres
kg
WAP0040
40
25
1/2" Male
13
8
WIP0040
40
25
1/2" Male
13
8
Ensure that all the equipment and accessories are suitable