4
Instruction Manual
Hydrostatic Test Hand Pumps WIP0040, WAP0040
MAINTENACE
-
Regularly grease the pump piston (8) and clean the intake filter (14) and the valves.
-
Regularly check unit and hose for damages.
-
In case of pump malfunctioning (required pressure is not achieved; the pump doesn't work with regularity; the
pump does not keep pressure):
•
Check if intake filter is clean.
•
Check outflow valve: unscrew the plug (18), take the spring (19) and the ball (20). Clean the ball. Put the
ball and the spring inside the valve. Screw the tap.
-
Use only original spare parts. All repair and maintenance works must be performed only by specialist personnel or
by people familiar with the pump.
-
If you decide not to use more the pump, don't let unauthorized people use the unit.
1
LEVER HANDLE
2
LEVER
3
SEEGER RING (x6)
4
LEVER SUPPORT (x2)
5
PIN (x2)
6
LONG PIN
7
LEVER BLOCKING (OPTIONAL)
8
PISTON
9
SEAL
10 BALL
11 SEAL
12 SCREW (x5)
13 PUMP BODY
14 INTAKE FILTER
15 OUTFLOW PIPE
16 OUTFLOW TAP
17 SEAL
18 PLUG
19 SPRING
20 BALL
21 SEAL
22 GAUGE
24 TANK PLATE
25 SCREW (x2)
26 TANK
27 NUT (x4)
28 HOSE
The pump must always be handled and repaired by qualified personnel.