Issue 1

Page 14 of 24

EL-SMS-2G-TP / TP+ / PROBE-G USER MANUAL

User Guide

SMS Retry Process (Continued)

The unit uses the retry sequence shown in the above diagram when attempting to
send either a temperature alert or battery low message:

During the retry process, any other pending notification messages will be

postponed.

The unit will assume that a notification message has been successfully delivered as

long as the message was successfully transferred to the mobile network for at least
one of the programmed numbers.

If after following the above retry sequence, a notification message still can’t be sent

to the mobile network, then the alert will be cancelled and the unit will continue
normal operation looking for new alert conditions to occur. If the cancelled message

was an alarm notification the alarm condition may still be reported in the following:

1) The alarm history in the next alarm message.

2) Most recent alarm in the next summary message.

The unit will only make one attempt to send a summary message. If the attempt
is unsuccessful then the summary message will be cancelled. Regardless of the
outcome the minimum, maximum and average temperature data for the period will
be reset.

1EasyLog Office; ,

6 ,5*#,55*50
00000000000000000
00000000000000000
000000000000000000
7*77224+2+225+2972
22272292,*222292 79
2222222*25*757+5#2
752262272522922522
2

Example screen shot of encrypted text

Security

The only way to change the configuration of a running ELSMS unit is to physically
go to the unit to initiate a new configuration sequence. If security in the end user

application is important then this should be considered when installing the unit.

Setting up the unit requires that someone is physically with the unit to begin the

setup sequence by pressing the “Status” button for five seconds. The configuration

message itself could be sent from any location so long as the person with the unit

can press the button in coordination with the person sending the configuration SMS.

The unit will accept a configuration message from any mobile device running the
App. Once a setup attempt has finished, the unit will no longer respond to incoming
messages unless a new setup is attempted. The configuration message sent to the

unit from the app is sent partially encrypted although the unit name is readable.

Summary of Contents for EL-SMS-2G-TP

Page 1: ...EL SMS 2G TP TP PROBE G USER MANUAL Temperature Monitor with SMS Alerts...

Page 2: ...your smartphone or tablet and and add a new device Use the mobile number that was supplied with your SIM card 7 If using Android select the device just added and press the Setup button 8 Con gure the...

Page 3: ...11 Setup Mode 11 Con guring the Unit 11 Run Mode 13 Stop Monitoring 13 SMS Retry Process 13 Security 14 Table of Contents Hardware Operation 15 Power Up LED Sequence 15 LED Flash Sequences 15 Netlight...

Page 4: ...3 Add the EL SMS device to your list by clicking the Add logger button at the lower right of the screen 4 Input the ELSMS device mobile number Optionally add a device name and notes regarding the devi...

Page 5: ...the icon for the device to a photo or reset it back to the default d DELETE DEVICE Removes the device from the App 6 Full Setup Tap the setting you wish to change See Fig 5 a Probe selection Allows y...

Page 6: ...bers that this ELSMS device should notify and select which messages they will receive See Fig 10 g Press the start button to send the con guration message to the EL SMS device 7 Viewing noti cations F...

Page 7: ...t to change 1 Download and install the App from the App Store iTunes 2 Open the App see Fig 1 Full Setup Con gure the device by tapping the options in the list 3 Select and enter the EL SMS device mob...

Page 8: ...fore a new alarm condition will be sent to you See Fig 5 8 Summary Interval The interval at which the ELSMS device will send you information regarding its status See Fig 6 9 Contact Information Input...

Page 9: ...Global System for Mobile Communications network to deliver the SMS noti cation messages and must be tted with a micro SIM card to allow them to connect to a GSM network and register These units use a...

Page 10: ...ever that actual delivery of the message is reliant on the mobile network and mobile operator s services operating normally User Guide Alarm Delay Operation These units allow a separate pre and post a...

Page 11: ...s ran at during operation When an attempt to setup the unit has been made and does not complete successfully User Guide When the unit is in run mode and the stop monitoring button sequence is pressed...

Page 12: ...to delays inherent in the GSM network such as network outages over subscription routine maintenance work message centre technical issues etc If a setup attempt does fail you can simply repeat the set...

Page 13: ...ondition is detected a battery low noti cation message will be sent The buttons are disabled whenever the unit is actively sending an SMS Stop Monitoring When the unit is in Run mode it can be put bac...

Page 14: ...n the summary message will be cancelled Regardless of the outcome the minimum maximum and average temperature data for the period will be reset 1EasyLog O ce 6 5 55 50 00000000000000000 00000000000000...

Page 15: ...es Low battery Medium priority 1 green ash Running no alarm conditions Low priority Stop monitoring Green LED on for 3s then o for 3s followed by reset Unit Con gured status is cleared SIM Card Error...

Page 16: ...mber has been con gured Using additional destination numbers will reduce the expected battery life User Guide Aerial and Signal Strength The unit uses a built in aerial to connect to the mobile networ...

Page 17: ...l time of the device used to send the con guration message by the amount that the con guration message was delayed Also note that the real time clock will be reset if the batteries are removed The clo...

Page 18: ...mation Date Time eld for con rmation that the real time clock has been set Current temperature Signal strength in bars where one is poor signal and ve is excellent signal Programmed rmware version Uni...

Page 19: ...h the message PrbErr followed by O or C for missing or broken probes Summary Message The summary message is sent at the interval speci ed when the unit was con gured The following information is shown...

Page 20: ...for a short circuit probe error probably caused by a faulty probe Setup Complete No SMS Rxd message report the probe errors as follows PrbErr Open is displayed for a disconnected probe error open circ...

Page 21: ...oduct may lead to excessive operating costs SMS Delivery SMS text messaging is a store and forward messaging system which uses message service centres to temporarily store messages until they can be d...

Page 22: ...signal strength shown in the last summary message was su cient for reliable operation SMS message centre issues Normal operation will resume when the network service disruption has ended Incorrect de...

Page 23: ...G Module Class 4 2W 850 900MHz Class 1 1W 1800 1900MHz Internal Antenna Penta band Embedded Antenna 50 Ohm Impedance Linear Polarisation 3dBi Gain VSWR 3 1 Battery Life 1 Year at 25 C daily summary me...

Page 24: ...major network operators infrastructure and generally o er their own customer service billing support systems marketing and sales personnel Short Message Service SMS Text messaging service allowing sho...

Page 25: ...EL SMS 2G TP TP PROBE G USER MANUAL Temperature Monitor with SMS Alerts...

Reviews: