background image

DIMENSIONS

All dimensions in mm (inches)

BATTERY REPLACEMENT

We recommend that you replace the battery every 12 months, or prior to logging critical data.

The EL-USB-1 does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging 
process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC.

Only use 3.6V 1/2AA lithium batteries. Check with your supplier that the battery  you are ordering is ‘press fit’ and is not fitted with solder 

tags. Before replacing the battery, remove the EL-USB-1 from the PC.

Note:

Leaving the EL-USB-1 plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost.

WARNING

Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations.

EL-USB-1          

Temperature Data Logger with USB Interface

98.0 (3.86)

26.0 (1

.02)

Internal Temperature Sensor Location

www.lascarelectronics.com 

    

26.8 (1

.05)

         Specifications liable to change without prior warning   

      Issue 12         07/2012                     S.L                  Applies to EL-USB-1              Page 3 of 4

Summary of Contents for EL-USB-1

Page 1: ...indows control software Environmental protection to IP67 ORDERING INFORMATION Standard Data Logger Data Logger Software on CD Battery Replacement Battery EL USB 1 BAT 3V6 1 2AA Specifications liable to change without prior warning Issue 12 07 2012 S L Applies to EL USB 1 Page 1 of 4 www lascarelectronics com At 25 C and 1 m logging rate Specifications Minimum Typical Maximum Unit Measurement range...

Page 2: ...r Green double flash The data logger is not currently logging but is primed to start at a later date and time delayed start Green single flash The data logger is currently logging No alarm Green and Orange single flash The data logger is full and has stopped logging No alarm Red single flash The data logger is currently logging Low alarm Red and Orange single flash The data logger is full and has ...

Page 3: ...th your supplier that the battery you are ordering is press fit and is not fitted with solder tags Before replacing the battery remove the EL USB 1 from the PC Note Leaving the EL USB 1 plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost WARNING Handle lithium batteries carefully observe warnings on battery casing Dispose of in accordance with loc...

Page 4: ...cy temperature humidity dew point 35 to 80 C 31 to 176 F 0 to 100 RH 0 3ºC 0 6ºF 2 0 RH 1 5ºC 3ºF 4 0 RH 16 382 3 6V AA 1 year EL USB 2 LCD Temperature humidity dew point with LCD 35 to 80 C 31 to 176 F 0 to 100 RH 0 5ºC 1ºF 3 0 RH 2ºC 4ºF 6 0 RH 16 379 3 6V AA 1 year EL USB 2 LCD Increased accuracy tem perature humidity dew point with LCD 35 to 80 C 31 to 176 F 0 to 100 RH 0 3ºC 0 6ºF 2 0 RH 1 5º...

Reviews: