Calibrating Tracer for Jaw 3:
1. Never have a “Cutter” or “Stylus” installed
while calibrating the Tracer, leave the collet
empty or it will get in the way of the Tracer
and cause an error.
2. Flip the tracer arm down with the “red knurl
knob” on the left side of the head.
3. On the main screen, click on the
“Operations” menu and choose “Calibrate
Tracer”
4. When the window appears asking to “Select
Jaw” insert the correct jaw number in the
window, (1, 2, or 3 depending on which jaw
you want to
calibrate) as we are calibrating Jaw “3” we
would enter “3” and click “OK”
5. The tracer tip will touch the jaw in three
places. After the procedure is complete it will
read, “Update in Progress Please Wait” give it
a moment and don’t click anything or it can
possibly freeze the software and you will have
to restart it.